Evaluation du couloir osseux pour vissage trans-iliaque et trans sacral et ses applications cliniques: étude de simulation informatique
Assessment of osseous corridor for transiliac–transsacral screws and clinical applications: Computational simulation study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- Scopus
- 저널 순위
- Scopus Q4
- 저널
- Revue de Chirurgie Orthopedique et Traumatologique106(5) · pp.500 · 2020
- 피인용
- Scopus 0
- FWCI (Scopus)
- 0
- ISSN
- 1877-0517
저자
- Kim, Young-Woo제1저자Department of Orthopaedic Surgery, Catholic University, Uijeongbu St. Mary's Hospital, Uijeongbu, Démocratique de Corée
- 장재훈Department of Orthopaedic Surgery, Trauma Center, Pusan National University Hospital, 179, Gudeok-ro, Seo-gu, 49241 Busan, Démocratique de Corée
- Jung, Gu-Hee교신저자Department of Orthopaedic surgery, Gyeongsang national university, college of medicine and Gyeongsang national university Changwon hospital, 11, Samjeongja-ro, Seongsan-gu, Changwon-si, 51472 Gyeongsangnam-do, Démocratique de Corée
초록
Background: Transiliac-transsacral (TITS) screw fixation might be necessary in some cases involving the vertical shearing injuries with transforaminal fracture and bilateral posterior ring injuries. However, the possibility of S1 TITS screw should be preoperatively assessed because the pelvic ring injuries with sacral dysmorphism had the insufficient osseous corridors. Hypothesis: AxWS2 may predict the possibility of TITS screw fixation and be used as the new indicator to discriminate the sacral dysmorphism. Materials and methods: The conventional CT images of Eighty-two cadaveric pelvis imported into Mimics® software to reconstruct three-dimensional (3D) models. A 7.0-mm-sized screw was processed into a 3D model using a 3D-sensor at actual size and virtually implanted as S1 and S2 TITS screw using Mimics® software. The cortical violation around screw path was evaluated using 3D biplanar and conventional CT images. The osseous corridor widths around TITS screws were measured in the axial plane images and defined as AxWS1 and AxWS2, respectively. Results: Despite no cortical violation in S2 of all models, cortical violation of S1 TITS screw was found in 20 models. Of them, 14 models (impossible models) were identified in the 3D biplanar images, and all 20 models (CT-violation models) were identified only in CT axial plane images. AxWS1 was < 7 mm in the impossible models and < 9.0 mm in the CT-violation models. AxWS2 negatively correlated with AxWS1 (R 0.450, p < 0.01). By receiver operating characteristic curve analysis to identify the CT-violation model using AxWS2, the cut-off value of AxWS2 was 13.32 mm (sensitivity 0.70, specificity 0.70). Discussion: By using AxWS2, The possibility of S1 TITS screw fixation could be predicted and safely placed without cortical violation, if AxWS2 was less than 13 mm. Considering the negative relationship with AxWS1, AxWS2 should be used as new indicator to predict safe S1 TITS screw fixation. Level of evidence: III, controlled laboratory study.
키워드
Cortical violationIliosacral screwPelvic ring injuryTransiliac-transsacral screw fixation
식별자
- Scopus EID
- 2-s2.0-85089356594



로그인
연구물 목록으로