Experimental Study on the Behavior of Existing Reinforced Concrete Multi-Column Piers under Earthquake Loading
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- APPLIED SCIENCES-BASEL11(6) · 2021
- 피인용
- Web of Science 4Scopus 6
- FWCI (Scopus)
- 0.15
- JCR IF
- JCR 2020 2.679
- ISSN
- 2076-3417
저자
- 김정한제1저자Department of Civil Engineering, Pusan National University;, Busan, 46241, Korea;
- Kim, Ick-HyunDepartment of Civil and Environmental Engineering, University of Ulsan, Ulsan, 44610, Korea;
- Lee, Jin Ho교신저자Department of Ocean Engineering, Pukyong National University;, Busan, 48513, Korea
초록
When a seismic force acts on bridges, the pier can be damaged by the horizontal inertia force of the superstructure. To prevent this failure, criteria for seismic reinforcement details have been developed in many design codes. However, in moderate seismicity regions, many existing bridges were constructed without considering seismic detail because the detailed seismic design code was only applied recently. These existing structures should be retrofitted by evaluating their seismic performance. Even if the seismic design criteria are not applied, it cannot be concluded that the structure does not have adequate seismic performance. In particular, the performance of a lap-spliced reinforcement bar at a construction joint applied by past practices cannot be easily evaluated analytically. Therefore, experimental tests on the bridge piers considering a non-seismic detail of existing structures need to be performed to evaluate the seismic performance. For this reason, six small scale specimens according to existing bridge piers were constructed and seismic performances were evaluated experimentally. The three types of reinforcement detail were adjusted, including a lap-splice for construction joints. Quasi-static loading tests were performed for three types of scale model with two-column piers in both the longitudinal and transverse directions. From the test results, the effect on the failure mechanism of the lap-splice and transverse reinforcement ratio were investigated. The difference in failure characteristics according to the loading direction was investigated by the location of plastic hinges. Finally, the seismic capacity related to the displacement ductility factor and the absorbed energy by hysteresis behavior for each test were obtained and discussed.
키워드
reinforced concrete columnmulti-column pierseismic behaviorlap-splicetransverse reinforcementplastic hingeductility
식별자
- Scopus EID
- 2-s2.0-85118958029
- WoS UID
- 000645789200001



로그인
연구물 목록으로