Deep Learning Based Airway Segmentation Using Key Point Prediction
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- APPLIED SCIENCES-BASEL11(8) · 2021
- 피인용
- Web of Science 21Scopus 22
- FWCI (Scopus)
- 1.03
- JCR IF
- JCR 2020 2.679
- ISSN
- 2076-3417
저자
- 박진영제1저자Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 황재준Department of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 류지혜Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 남인혜Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 김솔아Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 조봉혜Department of Oral and Maxillofacial Radiology, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 신상훈Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
- 이재열교신저자Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, 50612, Korea;
초록
The purpose of this study was to investigate the accuracy of the airway volume measurement by a Regression Neural Network-based deep-learning model. A set of manually outlined airway data was set to build the algorithm for fully automatic segmentation of a deep learning process. Manual landmarks of the airway were determined by one examiner using a mid-sagittal plane of cone-beam computed tomography (CBCT) images of 315 patients. Clinical dataset-based training with data augmentation was conducted. Based on the annotated landmarks, the airway passage was measured and segmented. The accuracy of our model was confirmed by measuring the following between the examiner and the program: (1) a difference in volume of nasopharynx, oropharynx, and hypopharynx, and (2) the Euclidean distance. For the agreement analysis, 61 samples were extracted and compared. The correlation test showed a range of good to excellent reliability. A difference between volumes were analyzed using regression analysis. The slope of the two measurements was close to 1 and showed a linear regression correlation (r(2) = 0.975, slope = 1.02, p < 0.001). These results indicate that fully automatic segmentation of the airway is possible by training via deep learning of artificial intelligence. Additionally, a high correlation between manual data and deep learning data was estimated.
키워드
식별자
- Scopus EID
- 2-s2.0-85104737978
- WoS UID
- 000644010500001



로그인
연구물 목록으로