본문 바로가기

Developed hydrogen liquefaction process using liquefied natural gas cold energy: Design, energy optimization, and techno-economic feasibility

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
INTERNATIONAL JOURNAL OF ENERGY RESEARCH45(10) · pp.14745 · 2021
피인용
Web of Science 65Scopus 70
FWCI (Scopus)
2.41
JCR IF
JCR 2020 5.164
ISSN
0363-907X

저자

  1. Cho, Seungsik제1저자Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea
  2. Park, JinwooDepartment of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea
  3. 노원준School of Chemical and Biomolecular Engineering, Pusan National University, Busan, Republic of Korea
  4. 이인규교신저자School of Chemical and Biomolecular Engineering, Pusan National University, Busan, Republic of Korea
  5. Moon, Il교신저자Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Republic of Korea

초록

This study focuses primarily on improving large-scale hydrogen liquefaction process by integrating liquefied natural gas (LNG) stream to utilize LNG cold energy. For the hydrogen liquefaction process, a large amount of energy is required for the compression and the cryogenic refrigeration system. LNG is one of the main sources for producing hydrogen, and it can be an opportunity to save energy because LNG cold energy is normally discarded into seawater during regasification. The objective of this study is to reduce the specific energy consumption and specific liquefaction cost. The proposed design which produces 300 ton/day of liquid hydrogen is compared with a base case design comprising two-stage mixed refrigerant refrigeration cycles. To minimize the specific energy consumption, multiparameter optimization is conducted by connecting simulation results to a genetic algorithm. Through the optimization, the flow rates of LNG and MR in the precooling cycle decrease by 1.08 and 21.00 kg/s, respectively. The specific energy consumption is reduced from 4.36 to 4.07 kWh/kg-LH2. Particularly, in the precooling cycle where the LNG stream is integrated, it decreases by more than 26.40%. Regarding the specific liquefaction cost of hydrogen liquefaction, the capital expenses are reduced by 15.16%, and annual operating expenses are diminished by 9.05%. Therefore, the total specific cost liquefaction shows a reduction of approximately 7.7%. Overall, an efficient hydrogen liquefaction process will provide a guideline for LNG-dependent countries by reducing the specific energy consumption and the specific liquefaction cost by recovering the waste cold energy.

키워드

cold energy utilizationhydrogen liquefactionmultiparameter optimizationspecific energy consumptionspecific liquefaction cost

식별자

Scopus EID
2-s2.0-85104250756
WoS UID
000640012600001