Numerical Study of the Flow Uniformity Inside the High-Pressure Side Manifolds of a Cooled Cooling Air Heat Exchanger
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- APPLIED THERMAL ENGINEERING189 · 2021
- 피인용
- Web of Science 22Scopus 27
- FWCI (Scopus)
- 1.13
- JCR IF
- JCR 2020 5.295
- ISSN
- 1359-4311
저자
- 칼라쓰 하리하란제1저자School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
- 콜리 포스터 콰메School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
- 진칭예School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
- 하만영School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
- 박상후School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
- Kim, Hyeon-junR&D Center, Donghwa Entec, 7, Gwahaksandan-ro 305beon-gil, Gangseo-gu, Busan, 46742, Republic of Korea
- Chetwynd-Chatwin, JasonRolls-Royce plcKingdom, Whittle House, WH76, PO Box 3, Filton, Bristol BS34 7QE, United Kingdom
- 민준기교신저자School of Mechanical Engineering, Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea
초록
To maintain efficiency in advanced aero-engines, it is crucial to set high limits for the Operating Pressure Ratio (OPR) and Turbine Entry temperature (TET). This can be achieved using a Cooled Cooling Air (CCA) heat exchanger, which precools the compressed air with the bypass stream before the compressed air enters the turbine to cool the blades. The aim of the present study was to improve the aero-thermal performance of CCA heat exchangers by enhancing the uniformity of flow through its high-pressure (HP) side manifolds. The development of the new manifolds was constrained by their manufacturability, as well as the pressure drop across the heat exchanger. The inlet and outlet manifold geometries are parameterised, and Computational Fluid Dynamic (CFD) simulations are carried out for Maximum Take-Off (MTO) conditions. Shape changes were performed using the mesh morphing tool, which enabled the intermediate remeshing steps to be skipped. By means of regression analysis, it was possible to find inlet and exit manifolds with improved flow uniformity; the heat transfer, structural integrity, and weight of the baseline and new manifolds were then evaluated. The new manifolds were structurally sound, and showed an 18.8% improvement in uniformity, a 10.6% reduction in pressure drop, a 0.4% increase in heat transfer rate, and a 22.5% decrease in weight.
키워드
식별자
- Scopus EID
- 2-s2.0-85101774168
- WoS UID
- 000635629300007



로그인
연구물 목록으로