본문 바로가기

Computational models for structural crashworthiness analysis in fires

문서 유형
연구출판물 · 저서
등재
Scopus
저널 순위
Scopus Q4
피인용
Scopus 0
FWCI (Scopus)
0
ISSN
1566-0443

저자

  1. 백점기제1저자교신저자The Korea Ship and Offshore Research Institute (Lloyd’s Register Foundation Research Centre of Excellence), Pusan National University, Busan, Korea (Republic of)

초록

Structures and infrastructures in fires inevitably experience nonlinear structural consequences as a result of fire loads, such as elevated temperatures and heat fluxes (as described in Chap. 8). Such analysis is a key task within the framework of quantitative fire risk assessment and management (as described in Chap. 16). Two methods of structural crashworthiness analysis in fires are relevant, namely the one-way method and the two-way method. The one-way method is a sequential approach in which the prediction of the fire load profile, heat transfer analysis, and structural response analysis are conducted sequentially in a single way. Furthermore, the interacting effects between fire loads (e.g., temperatures) and structural responses (e.g., deformations and structural failures) with time are not accounted for. The two-way method is an approach that captures fire consequences more realistically. Specifically, fire load prediction, nonlinear structural response analysis, and heat transfer analysis are conducted simultaneously. Furthermore, this approach considers the “fluid-structure interaction” (FSI) effect. This chapter presents computational models for both the heat transfer analysis and the nonlinear structural response analysis in fires.

식별자

Scopus EID
2-s2.0-85070712504