Convolutional neural network-based ambient light-independent panel digit surveillance technique for infusion pumps
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q4Scopus Q2
- 저널
- PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE235(5) · pp.566 · 2021
- 피인용
- Web of Science 3Scopus 3
- FWCI (Scopus)
- 0.17
- JCR IF
- JCR 2020 1.617
- ISSN
- 0954-4119
저자
- 황영준제1저자Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
- 김건호Interdisciplinary Program in Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, Korea
- 성의숙Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
- 남경원교신저자Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
초록
For effective patient therapy and improved patient safety, it is critical to administer medication accurately in accordance with doctor's prescription. However, accidents owing to the erroneous programing of infusion pumps caused by users have been consistently reported in several documents. In this study, the authors propose a novel surveillance technique for infusion pumps to continuously monitor the variations in panel digits using a convolutional neural network model, and evaluate the performance of the implemented technique. During the experimental evaluation, 1st-step ROIs and 2nd-step ROIs were successfully extracted from the frame images regardless of the ambient lighting conditions. The final accuracies of the implemented CNN model are 99.9% for both the training (172,800 images) and validation (1080 images) dataset while the final losses for the training and validation datasets are 0.48 and 0.45 after 13th epoch, respectively. In the 24-h continuous monitoring test, the accuracy of the model for volume recognition considering all the 1440 measurements (960 for day-lighting and 480 for night-lighting) is 95.5%, whereas in day-lighting and night-lighting modes the accuracies of the model are 98.2% and 90.0%, respectively. Based on these experimental results, the proposed surveillance technique incorporating infusion pumps is expected to improve the safety of patients who need long-term treatments via infusion pumps, reducing the burden on the nurses and hospitals.
키워드
Infusion pumpmonitoringdeep learningconvolutional neural networkpatient safety