A numerical study on the flow control characteristic of a cavitating venturi with one- and two-stage diffusers
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q3Scopus Q2KCI Q2
- 저널
- JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY35(4) · pp.1463 · 2021
- 피인용
- Web of Science 8Scopus 9KCI 2
- FWCI (Scopus)
- 0.45
- JCR IF
- JCR 2020 1.734
- ISSN
- 1738-494X
저자
초록
A cavitating venturi in the auxiliary feed water system of a nuclear power plant is a flow control device that limits the maximum flow rate in critical conditions. In this research, a numerical study was conducted to predict the characteristics of the cavitating flow in a venturi with various geometrical configurations. Assuming axisymmetric geometry and a steady state, equations of the flow field were solved numerically. The mixture model for the multi-phase flow and the standard k-epsilon turbulence model were adopted. The primary diffuser angle was varied to perform detailed parametric study. The flow and pressure variations, shape of the cavitation bubble, and corresponding flow control characteristics were summarized. Finally, the calculation results were analyzed to provide a physical basis for the design limits proposed in a previous patent. It is expected that the results of this study will be useful information for the future design of an optimized venturi.
키워드
CavitationCavitating venturiChoking flowComputational fluid dynamic