Evaluation of 3D Templated Synthetic Vascular Graft Compared with Standard Graft in a Rat Model: Potential Use as an Artificial Vascular Graft in Cardiovascular Disease
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q2
- 저널
- MATERIALS14(5) · 2021
- 피인용
- Web of Science 19Scopus 20
- FWCI (Scopus)
- 1.2
- JCR IF
- JCR 2020 3.623
- ISSN
- 1996-1944
저자
- Sohn, Sung-Hwa제1저자Department of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
- Kim, Tae HeeAdvanced Textile R&D Department, Korea Institute of Industrial Technology, Ansan, 15588, Korea
- Kim, Tae SikDepartment of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
- Min, Too JaeDepartment of Anesthesiology and Pain Medicine, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
- Lee, Ju-HanDepartment of Pathology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
- Yoo, Sung MookDepartment of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
- Kim, Ji-WonDepartment of Anesthesiology and Pain Medicine, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
- Lee, Ji EunAdvanced Textile R&D Department, Korea Institute of Industrial Technology, Ansan, 15588, Korea
- Kim, Chae HwaAdvanced Textile R&D Department, Korea Institute of Industrial Technology, Ansan, 15588, Korea
- 박석희교신저자School of Mechanical Engineering, Pusan National University, 2 Busandaehak‐ro, 63 beon‐gil, Geumjeong‐gu, Busan, 46241, Korea
- Jo, Won-Min교신저자Department of Thoracic & Cardiovascular Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Korea
초록
Although the number of vascular surgeries using vascular grafts is increasing, they are limited by vascular graft-related complications and size discrepancy. Current efforts to develop the ideal synthetic vascular graft for clinical application using tissue engineering or 3D printing are far from satisfactory. Therefore, we aimed to re-design the vascular graft with modified materials and 3D printing techniques and also demonstrated the improved applications of our new vascular graft clinically. We designed the 3D printed polyvinyl alcohol (PVA) templates according to the vessel size and shape, and these were dip-coated with salt-suspended thermoplastic polyurethane (TPU). Next, the core template was removed to obtain a customized porous TPU graft. The mechanical testing and cytotoxicity studies of the new synthetic 3D templated vascular grafts (3DT) were more appropriate compared with commercially available polytetrafluoroethylene (PTFE) grafts (ePTFE; standard graft, SG) for clinical use. Finally, we performed implantation of the 3DTs and SGs into the rat abdominal aorta as a patch technique. Four groups of the animal model (SG_7 days, SG_30 days, 3DT_7 days, and 3DT_30 days) were enrolled in this study. The abdominal aorta was surgically opened and sutured with SG or 3DT with 8/0 Prolene. The degree of endothelial cell activation, neovascularization, thrombus formation, calcification, inflammatory infiltrates, and fibrosis were analyzed histopathologically. There was significantly decreased thrombogenesis in the group treated with the 3DT for 30 days compared with the group treated with the SG for 7 and 30 days, and the 3DT for 7 days. In addition, the group treated with the 3DT for 30 days may also have shown increased postoperative endothelialization in the early stages. In conclusion, this study suggests the possibility of using the 3DT as an SG substitute in vascular surgery.