본문 바로가기

Analysis of access flow using duplex ultrasonography and the ultrasound dilutional method

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q2
저널
JOURNAL OF VASCULAR ACCESS23(2) · pp.286 · 2022
피인용
Web of Science 5Scopus 5
FWCI (Scopus)
0.56
JCR IF
JCR 2021 2.326
ISSN
1129-7298

저자

  1. 배미주제1저자Department of Thoracic and Cardiovascular Surgery, Pusan National University Hospital, Busan, Republic of Korea
  2. 전창호교신저자Department of Radiology, Pusan National University Hospital, Busan, Republic of Korea
  3. 한미연Department of Internal Medicine, Hallym University Hangang Sacred Heart Hospital, Seoul, Republic of Korea
  4. 진모란Department of Thoracic and Cardiovascular Surgery, Pusan National University Hospital, Busan, Republic of Korea
  5. 김효진Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea

초록

Background: This study aimed to evaluate the correlation between duplex ultrasonography (DUS) and ultrasound dilution (UD) measurement's results and determine the factors affecting the correlation of the measured values among other clinical factors in patients. Methods: This cross-sectional study was conducted from April 2020 to May 2020 and included 60 patients who visited our dialysis centre. The flow of the fistula was measured in the proximal brachial artery using DUS. While dialysis was performed on the same day, the access flow was measured using the UD method. The correlation and agreement between the access flows acquired by each measurement method were analysed. Similarly, the correlation was analysed by classifying the groups based on the predisposing factor, and statistically significant factors were observed through comparison. Results: Both measurements showed a moderate positive correlation (r = 0.60, p < 0.01). The bias (mean of UD-DUS) between the two measurements was about 230 mL/min. When the measurement site of DUS was near the inflow artery and in the same anatomical section, a strong correlation with the measurement value of UD was observed (brachial based fistula: r = 0.85, radial based fistula: r = 0.87). Similarly, for patients without diabetes and those who regularly underwent access surveillance for the dialysis route, strong correlations were observed between the two measurements (r = 0.79 and r = 0.88). Conclusions: Several factors can influence the correlation between UD and DUS. The findings showed a high correlation for DUS measurement sites within the same anatomical section as the inflow artery, patients without diabetes, and patients undergoing periodic surveillance.

키워드

Arteriovenous fistulasurveillanceultrasound dilution technologyduplex ultrasonography

식별자

Scopus EID
2-s2.0-85100464961
WoS UID
000631240400001