Comparison of new implantation of cardiac implantable electronic device between tertiary and non-tertiary hospitals: a Korean nationwide study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- SCIENTIFIC REPORTS11(1) · 2021
- 피인용
- Web of Science 2Scopus 2
- FWCI (Scopus)
- 0.1
- JCR IF
- JCR 2020 4.38
- ISSN
- 2045-2322
저자
- Han, Seungbong제1저자Department of Biostatistics, College of Medicine, Korea University, Seoul, Korea
- Park, Gyung-MinDepartment of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
- Kim, Yong-Giun교신저자Department of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
- 황기원Division of Cardiology, Pusan National University Yangsan Hospital, Pusan National University of Medicine, Yangsan, Korea
- Kwon, Chang HeeDivision of Cardiology, Department of Internal Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea
- Roh, Jae-HyungDivision of Cardiology, Chungnam National University Sejong Hospital, Chungnam National University School of Medicine, Sejong, Korea
- Park, SangwooDepartment of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
- Won, Ki-BumDepartment of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
- Ann, Soe HeeDepartment of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
- Kim, Shin-JaeDepartment of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
- Lee, Sang-GonDepartment of Cardiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Korea
초록
This study compared the characteristics and mortality of new implantation of cardiac implantable electronic device (CIED) between tertiary and non-tertiary hospitals. From national health insurance claims data in Korea, 17,655 patients, who underwent first and new implantation of CIED between 2013 and 2017, were enrolled. Patients were categorized into the tertiary hospital group (n=11,560) and non-tertiary hospital group (n=6095). Clinical outcomes including in-hospital death and all-cause death were compared between the two groups using propensity-score matched analysis. Patients in non-tertiary hospitals were older and had more comorbidities than those in tertiary hospitals. The study population had a mean follow-up of 2.1 +/- 1.2 years. In the propensity-score matched permanent pacemaker group (n=5076 pairs), the incidence of in-hospital death (odds ratio [OR]: 0.76, 95% confidence interval [CI]: 0.43-1.32, p=0.33) and all-cause death (hazard ratio [HR]: 0.92, 95% CI 0.81-1.05, p=0.24) were not significantly different between tertiary and non-tertiary hospitals. These findings were consistently observed in the propensity-score matched implantable cardioverter-defibrillator group (n=992 pairs, OR for in-hospital death: 1.76, 95% CI 0.51-6.02, p=0.37; HR for all-cause death: 0.95, 95% CI 0.72-1.24, p=0.70). In patients undergoing first and new implantation of CIED in Korea, mortality was not different between tertiary and non-tertiary hospitals.
식별자
- Scopus EID
- 2-s2.0-85102600749
- WoS UID
- 000630515000001



로그인
연구물 목록으로