Evaporator Optimization of Refrigerator Systems Using Quality Analysis
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q1
- 저널
- ENERGIES14(3) · 2021
- 피인용
- Web of Science 7Scopus 8
- FWCI (Scopus)
- 0.28
- JCR IF
- JCR 2020 3.004
- ISSN
- 1996-1073
저자
- 나상경제1저자School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
- Song, SanghunLG Electronics, 391-2, Changwon, 51533, Korea
- 이승혁School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
- 이제환School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
- Kim, HyunLG Electronics, 391-2, Changwon, 51533, Korea
- Lee, SungwooLG Electronics, 391-2, Changwon, 51533, Korea
- 최경민교신저자School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
- 안성율교신저자School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
초록
In this study, evaporator optimization, via both experimental and simulation methods was conducted. To evaluate the evaporator performance, under the optimal system, the compressor operating time and the effects of oil on the refrigerator system were studied. If the temperature of the refrigerator chamber reaches the setting value, the compressor stops working and it leads to the temperature of the refrigerator chamber slowly increasing, due to the heat transfer to the ambient. When the refrigerator temperature is out of the setting range, the compressor works again, and the refrigerator repeats this process until the end of its life. These on/off period can be controlled through the compressor piston movement. To determine the optimal compressor operating conditions, experiments of monthly power consumption were conducted under various compressor working times and the lowest power consumption conditions was determined when the compressor worked continuously. Lubricating oil, the refrigerator system, using oil, also influenced the system performance. To evaluate the effect of oil, oil eliminated and oil systems were compared based on cooling capacity and power consumption. The cooling capacity of the oil eliminated system was 2.6% higher and the power consumption was 3.6% lower than that of the oil system. After determining the optimal operating conditions of the refrigerator system, visualization experiments and simulations were conducted to decide the optimal evaporator and the conventional evaporator size can be reduced by approximately 2.9%.
키워드
refrigerator systemflow characteristics of refrigerantlubricating oil eliminationvisualization in evaporatorevaporator quality
식별자
- Scopus EID
- 2-s2.0-85106244587
- WoS UID
- 000615068300001



로그인
연구물 목록으로