Fabrication of Electrochemical Influenza Virus (H1N1) Biosensor Composed of Multifunctional DNA Four-Way Junction and Molybdenum Disulfide Hybrid Material
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q2
- 저널
- MATERIALS14(2) · 2021
- 피인용
- Web of Science 30Scopus 32
- FWCI (Scopus)
- 1.77
- JCR IF
- JCR 2020 3.623
- ISSN
- 1996-1944
저자
- Park, Jeong Ah제1저자Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul, 01897, Korea
- Kim, JinmyeongDepartment of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul, 01897, Korea
- Kim, Soo MinDepartment of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul, 01897, Korea
- Sohn, HiesangDepartment of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul, 01897, Korea
- Park, ChulhwanDepartment of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul, 01897, Korea
- Kim, Tae-HyungSchool of Integrative Engineering, Chung-Ang University, 84, Heukseok-ro, Seoul, 06974, Korea
- 이진호School of Biomedical Convergence Engineering, Pusan National University, 49, Busandaehak-ro, Yangsan, 50612, Korea
- Lee, Min-Ho교신저자School of Integrative Engineering, Chung-Ang University, 84, Heukseok-ro, Seoul, 06974, Korea
- Lee, Taek교신저자Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul, 01897, Korea
초록
The outbreak of the influenza virus (H1N1) has symptoms such as coughing, fever, and a sore throat, and due to its high contagious power, it is fatal to humans. To detect H1N1 precisely, the present study proposed an electrochemical biosensor composed of a multifunctional DNA four-way junction (4WJ) and carboxyl molybdenum disulfide (carboxyl-MoS2) hybrid material. The DNA 4WJ was constructed to have the hemagglutinin aptamer on the head group (recognition part); each of the two arms has four silver ions (signal amplification part), and the tail group has an amine group (anchor). This fabricated multifunctional DNA 4WJ can specifically and selectively bind to hemagglutinin. Moreover, the carboxyl-MoS2 provides an increase in the sensitivity of this biosensor. Carboxyl-MoS2 was immobilized using a linker on the electrode, followed by the immobilization of the multifunctional 4WJ on the electrode. The synthesis of carboxyl-MoS2 was confirmed by field emission scanning electron microscopy (FE-SEM), and the surface of the electrode was confirmed by atomic force microscopy. When H1N1 was placed in the immobilized electrode, the presence of H1N1 was confirmed by electrochemical analysis (cyclic voltammetry, electrochemical impedance spectroscopy). Through selectivity tests, it was also possible to determine whether this sensor responds specifically and selectively to H1N1. We confirmed that the biosensor showed a linear response to H1N1, and that H1N1 could be detected from 100 nM to 10 pM. Finally, clinical tests, in which hemagglutinin was diluted with human serum, showed a similar tendency to those diluted with water. This study showed that the multi-functional DNA 4WJ and carboxyl-MoS2 hybrid material can be applied to a electrochemical H1N1 biosensor.
키워드
electrochemical biosensorDNA 4WJinfluenza virusmolybdenum disulfide
식별자
- Scopus EID
- 2-s2.0-85099472409
- WoS UID
- 000611364300001



로그인
연구물 목록으로