Electrochemical immunoassay based on choline oxidase-peroxidase enzymatic cascade
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- BIOSENSORS & BIOELECTRONICS171 · 2021
- 피인용
- Web of Science 29Scopus 32
- FWCI (Scopus)
- 1.87
- JCR IF
- JCR 2020 10.618
- ISSN
- 0956-5663
저자
- 얀 카이제1저자Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
- 포누사미 난다쿠마르Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
- 바티아 아만Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
- Lee, Nam-SihkEONE Laboratories, Incheon, 22014, South Korea
- Yoon, Young HoEONE Laboratories, Incheon, 22014, South Korea
- 양해식교신저자Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Korea
초록
Horseradish peroxidase (HRP)-based electrochemical immunoassays are considered promising techniques for point-of-care clinical diagnostics, but the necessary addition of unstable H2O2 in the enzymatic system may hinder their practical application. Although glucose oxidase (GOx) has been widely explored for in situ generation of H2O2 in HRP-based immunoassay, the GOx-catalyzed reduction of oxidized peroxidase substrate may limit the immunosensing performance. Here, we report a sensitive electrochemical immunosensor based on a choline oxidase (ChOx)-HRP cascade reaction. In this design, ChOx catalyzes the oxidation of choline, during which H2O2 is generated in situ and thus oxidizes acetaminophen (APAP) in the presence of HRP. The electrochemical behavior of APAP in the ChOx-HRP cascade was compared with that of the commonly used GOx-HRP cascade, which confirmed that ChOx could be a superior preceding enzyme for sensitive immunoassay based on the bienzymatic cascade. The developed ChOx-HRP cascade was also further explored for a sandwich-type electrochemical immunoassay of parathyroid hormone in artificial and clinical serum. The calculated detection limit was similar to 3 pg/mL, indicating that the ChOx-HRP cascade is especially promising for highly sensitive electrochemical immunoassays when APAP is used as the peroxidase substrate.
키워드
Electrochemical immunoassayCholine oxidaseHorseradish peroxidaseEnzymatic cascadeParathyroid hormone detectionDIAPHORASE
식별자
- Scopus EID
- 2-s2.0-85092659965
- WoS UID
- 000603553700007



로그인
연구물 목록으로