Therapeutic response monitoring after targeted therapy in an orthotopic rat model of hepatocellular carcinoma using contrast-enhanced ultrasound: Focusing on inter-scanner, and inter-operator reproducibility

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
PLOS ONE15(12) · 2020
피인용
Web of Science 3Scopus 3
FWCI (Scopus)
0.05
JCR IF
JCR 2019 2.74
ISSN
1932-6203

저자

  1. 류화성제1저자Department of Radiology, Pusan National University Yangsan Hospital, Yangsan-si, Gyeongsangnam-do, Korea
  2. Kim, Jung Hoon교신저자Department of Radiology, Seoul National University Hospital, Jongno-gu, Seoul, Korea
  3. Lee, SeunghyunDepartment of Radiology, Seoul National University Hospital, Jongno-gu, Seoul, Korea
  4. Han, Joon KooDepartment of Radiology, Seoul National University Hospital, Jongno-gu, Seoul, Korea

초록

Purpose To assess therapeutic response monitoring after targeted therapy in an orthotopic rat model of hepatocellular carcinoma (HCC) using CEUS with focusing on inter-scanner and inter-operator reproducibility. Materials and methods For reproducibility, CEUS was performed using two different US scanners by two operators in sixteen rat models of HCC. Using perfusion analysis software (VueBox (R)), eleven parameters were collected, and intra-class correlation coefficient (ICC) was used to analyze reproducibility. Then seventeen rat models of HCC were divided into treatment group (n = 8, 30 mg/kg/day sorafenib for five days) and control group (n = 9). CEUS was performed at baseline and 14 days after first treatment, and changes of perfusion parameters were analyzed. Results In treatment group, CEUS perfusion parameters showed a significant change. The peak enhancement (PE, 2.50 x10(3)+/- 1.68 x10(3) vs 5.55x10(2)+/- 4.65x10(2), p = 0.010) and wash-in and wash out AUC ((WiWo)AUC, 1.07x10(5)+/- 6.48 x10(4) vs 2.65x10(4)+/- 2.25x10(4), p = 0.009) had significantly decreased two weeks after treatment. On the contrary, control group did not show a significant change, including PE (1.15 x10(3)+/- 7.53x10(2) vs 9.43x10(2)+/- 7.81 x10(2), p = 0.632) and (WiWo)AUC (5.09 x10(4)+/- 3.25x10(4) vs 5.92 x10(4)+/- 3.20x10(4), p = 0.646). For reproducibility, the various degrees of inter-scanner reproducibility were from poor to good (ICC: <0.01-0.63). However, inter-operator reproducibility of important perfusion parameters, including (Wi)AUC, (Wo)AUC, and (WiWo)AUC, ranged from fair to excellent (ICC: 0.59-0.93) in a different scanner. Conclusion Our results suggest that CEUS is useful for assessment of the treatment response after targeted therapy and with fair to excellent inter-operator reproducibility.

키워드

QUANTITATIVE-EVALUATIONCEUSSORAFENIBPERFUSIONMICROCIRCULATIONQUANTIFICATIONMICE