본문 바로가기

An Integrated Approach to Real-Time Acoustic Emission Damage Source Localization in Piled Raft Foundations

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q2
저널
APPLIED SCIENCES-BASEL10(23) · 2020
피인용
Web of Science 12Scopus 14
FWCI (Scopus)
0
JCR IF
JCR 2019 2.474
ISSN
2076-3417

저자

  1. Kim, Yong-Min제1저자Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Korea;
  2. Han, GyeolDepartment of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Korea;
  3. Kim, HyunwooDeep Subsurface Research Center, Korea Institute of Geoscience and Mineral Resources (KIGAM), Daejeon, 34132, Korea;
  4. 오태민Department of Civil and Environmental Engineering, Pusan National University (PNU), Busan 46241, Korea;
  5. Kim, Jin-SeopRadioactive Waste Disposal Research Division, Korea Atomic Energy Research Institute (KAERI), Daejeon, 34057, Korea
  6. Kwon, Tae-Hyuk교신저자Department of Civil and Environmental Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Korea;

초록

Acoustic emission (AE) has garnered significant interest as a promising way to detect the early-stage development of internal cracks and damage in underground and geotechnical structures, associated with natural disasters. Meanwhile, AE source localization techniques that can identify the damage location in a piled-raft foundation (PRF) are premature because of its complex geometry, although the PRF is a widely used deep foundation type for high-rise buildings. In this study, we propose an integrated approach to localize AE sources in the PRF by using the modified Akaike information criterion (AIC) method and examine its accuracy to mark with pile zones. We performed a series of experiments on a scaled PRF model at a ratio of 1:50, composed of one raft and 25 piles. The results demonstrate that the combined approach with the modified AIC method and the Simplex method can localize the AE source zones with good accuracy, greater than 95% on average. The suggested two-stage AIC picker shows accurate onset time determination, and hence, it significantly improves the accuracy, particularly effective for the signals with low signal-to-noise ratios. The approach exploiting the two-stage AIC picker can be readily used for automated real-time AE monitoring to detect crack generation and its location in buried foundations that cannot be inspected visually.

키워드

source localizationacoustic emissiondamagenon-destructive testpiled-raft foundationreal-time monitoringonset timeSOURCE LOCATIONIDENTIFICATIONPICKINGSIGNALS

식별자

Scopus EID
2-s2.0-85097393399
WoS UID
000597133500001