본문 바로가기

Force balance droplet entrainment model for the horizontal stratified flow condition

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 13Scopus 17
FWCI (Scopus)
0.75
JCR IF
JCR 2020 5.584
ISSN
0017-9310

저자

  1. 배병건제1저자aDepartment of Mechanical Engineering, Pusan National University, 63 beon-gil 2, Busandaehak-ro, Geumjeong-gu, Busan, 46241, Republic of Korea
  2. 김휘융aDepartment of Mechanical Engineering, Pusan National University, 63 beon-gil 2, Busandaehak-ro, Geumjeong-gu, Busan, 46241, Republic of Korea
  3. Kim, KyungdoobKorea Atomic Energy Research Institute, 989 beon-gil, Daedeok-daero, Yuseong-gu, Daejeon, 34057, Republic of Korea
  4. 정재준aDepartment of Mechanical Engineering, Pusan National University, 63 beon-gil 2, Busandaehak-ro, Geumjeong-gu, Busan, 46241, Republic of Korea
  5. 윤병조교신저자aDepartment of Mechanical Engineering, Pusan National University, 63 beon-gil 2, Busandaehak-ro, Geumjeong-gu, Busan, 46241, Republic of Korea

초록

Under the horizontal stratified flow condition, a droplet with a large interfacial area influences the mass, momentum, and heat transfer between the gas and liquid phases. In this study, we developed a force balance droplet entrainment rate model applicable to the horizontal stratified flow condition. This model is based on the balance of forces that act on the interfacial wave, which consists of an interfacial shear force, a surface tension force, and the force of gravity. In addition, the force balance droplet entrainment rate model includes constitutive relations for the parameters that are related to the geometry and the characteristics of the interfacial wave. This includes the wave frequency, wave height, wave slope, the wave velocity along the flow direction, and the lateral length of the interfacial wave along the circumferential direction of the flow pipe. The prediction of the onset of entrainment by the proposed force balance droplet entrainment rate model was compared to that with the existing models. Subsequently, the model was evaluated with the latest droplet deposition rate correlation from the literature against the experimental data obtained under the horizontal stratified flow condition. It showed a good prediction capability with a MAPE of 15.34%. Finally, the applicability of the force balance droplet entrainment rate model to a large-sized pipe was investigated. The force balance model showed a reasonable prediction performance. The applicable ranges of the gas and liquid Reynolds numbers (Re-g and Re-l, respectively) proposed by droplet entrainment rate model are 65,500-571,400 and 170-11,000, respectively. (C) 2020 Elsevier Ltd. All rights reserved.

키워드

droplet entrainment rateforce balanceinterfacial wavehorizontal stratified flowonset of entrainmentdroplet deposition rate

식별자

Scopus EID
2-s2.0-85096924187
WoS UID
000596070000030