본문 바로가기

Reagentless Amperometric Pyruvate Biosensor Based on a Prussian Blue- and Enzyme Nanoparticle-Modified Screen-Printed Carbon Electrode

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q2
저널
ACS OMEGA5(46) · pp.30123 · 2020
피인용
Web of Science 24Scopus 26
FWCI (Scopus)
0
JCR IF
JCR 2019 2.87
ISSN
2470-1343

저자

  1. 띠루말라이 디나카란제1저자Department of Cogno-Mechatronics Engineering, Department of Optics and Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea;
  2. 김성혜교신저자Department of Chemistry, Chemistry Institute for Functional Materials, Sustainable Utilization of Photovoltaic Energy Research Center, Pusan National University, Busan 46241, Republic of Korea;
  3. 김석만교신저자Department of Chemistry, Chemistry Institute for Functional Materials, Sustainable Utilization of Photovoltaic Energy Research Center, Pusan National University, Busan 46241, Republic of Korea;
  4. 장승철Department of Cogno-Mechatronics Engineering, Department of Optics and Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea;

초록

We report a facile strategy for developing reagentless amperometric pyruvate biosensors based on enzyme nanoparticles (EnNPs). The EnNPs were prepared using pyruvate oxidase crosslinked with graphene quantum dots. Before EnNP immobilization, screen-printed carbon electrodes (SPCEs) were modified with Prussian blue, a biocompatible coordination polymer. The biosensor system was optimized in terms of the working potential and pH value. At pH 7.0 in 50 mM phosphate-buffered solution, the biosensor showed optimal characteristics under an applied potential of -0.10 V versus an internal pseudo-Ag reference electrode. Using these optimized conditions, the biosensor performance was characterized via the chronoamperometric technique. The EnNP-immobilized SPCE exhibited a dynamic linear range from 10 to 100 mu M for pyruvate solution, and a sensitivity of 40.8 mu A mM(-1) cm(-2) was recorded. The observed detection limit of the biosensor was 0.91 mu M (S/N = 3) and it showed strong anti-inference capability under the optimized working potential. Furthermore, the practical applicability of the proposed biosensor was studied in fish serum samples.

식별자

Scopus EID
2-s2.0-85096826537
WoS UID
000595527600049