본문 바로가기

Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
피인용
Web of Science 4Scopus 3
FWCI (Scopus)
0
JCR IF
JCR 2019 2.489
ISSN
0957-4530

저자

  1. 최정천제1저자Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  2. 박종하Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  3. 이한철교신저자Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  4. 박태식Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  5. 안진희Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  6. 박진섭Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  7. 이혜원Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  8. 오준혁Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  9. 최정현Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  10. 차광수Division of Cardiology, Medical Research Institute, Department of Internal Medicine, Pusan National University Hospital, Busan, Republic of Korea
  11. Yim, ChangyongDepartment of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea
  12. Jeon, SangminDepartment of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Republic of Korea

초록

Device-related problems of drug-eluting stents, including stent thrombosis related to antiproliferative drugs and polymers, can cause adverse events such as inflammation and neointimal hyperplasia. Stent surface modification, wherein the drug and polymer are not required, may overcome these problems. We developed hydrophilic polyethylene glycol (PEG)-coating and hydrophobic octadecylthiol (ODT)-coating stents without a drug and polymer and evaluated their histopathologic response in a porcine coronary restenosis model. PEG-coating stents (n=12), bare-metal stents (BMS) (n=12), and ODT-coating stents (n=10) were implanted with oversizing in 34 porcine coronary arteries. Four weeks later, the histopathologic response, arterial injury, inflammation, and fibrin scores were analyzed. A p value<0.05 was considered statistically significant. There were significant differences in the internal elastic lamina area, lumen area, neointimal area, percent area of stenosis, arterial injury score, inflammation score, and fibrin score among the groups. Compared to the BMS or ODT-coating stent group, the PEG-coating stent group had significantly increased internal elastic lamina and lumen area (all p<0.001) and decreased neointimal area and percent area of stenosis (BMS: p=0.03 and p<0.001, respectively; ODT-coating: p=0.013 and p<0.001, respectively). Similarly, the PEG-coating group showed significantly lower inflammation and fibrin scores than the BMS or ODT-coating groups (BMS: p=0.013 and p=0.007, respectively; ODT-coating: p=0.014 and p=0.008, respectively). In conclusion, hydrophilic PEG-coating stent implantation was associated with lower inflammatory response, decreased fibrin deposition, and reduced neointimal hyperplasia than BMS or hydrophobic ODT-coating stent implantation in the porcine coronary restenosis model.

식별자

Scopus EID
2-s2.0-85096867635
WoS UID
000595895100005