본문 바로가기

The Optimal Combination of Monochromatic and Metal Artifact Reconstruction Dual-energy CT to Evaluate Total Knee Replacement Arthroplasty

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
피인용
Web of Science 13Scopus 15
FWCI (Scopus)
0
JCR IF
JCR 2019 2.687
ISSN
0720-048X

저자

  1. 김지환제1저자Department of Radiology, Pusan National University Yangsan Hospital, Korea
  2. 박찬규교신저자Department of Radiology, Pusan National University Yangsan Hospital, Korea
  3. 정희석Department of Radiology, Pusan National University Yangsan Hospital, Korea
  4. 송유선Department of Radiology, Pusan National University Hospital, Korea
  5. 이인숙Department of Radiology, Pusan National University Hospital, Korea
  6. Jung, YunsubDeputy General Manager, CT Research Team, GE Healthcare Korea
  7. 이상민Department of Orthopedic Sugery, Pusan National University Yangsan Hospital, Korea

초록

Purpose: To evaluate the effects of gemstone spectral imaging-metal artifact reduction (GSI-MAR) on different dual-energy CT monochromatic images for patients with total knee replacement arthroplasty (TKRA) and to identify an appropriate protocol for clinical practice. Method: We enrolled 34 patients with TKRA. CT images were iteratively reconstructed with or without GSI-MAR at different energy levels (70, 95, 115, and 140 keV). Two radiologists evaluated the objective and subjective image qualities and MAR-related new artifacts at the femoral and tibial levels. For objective analysis, the mean CT number and image noise of the selected regions of interest in the bone and muscle were recorded. To quantitatively evaluate the performance of GSI-MAR, a structural similarity index (SSIM) was used. For subjective analysis, streak artifacts and diagnostic confidence in detecting periprosthetic complications were assessed. Objective and subjective indicators were compared among the image combinations. Results: In the femoral component, 140 keV monochromatic energy images with GSI-MAR showed the lowest mean CT number, image noise, SSIM value, and streak artifacts, and the best diagnostic confidence. In the tibial component, the image noise differed significantly, but the SSIM and subjective indicators were similar among the image combinations. MAR-related new artifacts were noted in 14.7% of images, and all of them were observed in only the femoral component. Conclusion: GSI-MAR with higher-energy monochromatic images showed fewer metal artifacts and better visualization. We recommend 140 keV with GSI-MAR for improving image quality and 140 keV without GSI-MAR for identifying MAR-related new artifacts when evaluating TKRA.

키워드

ArthroplastyReplacementKneeKnee ProsthesisArtifactsTomographyX-Ray ComputedTOTAL JOINT ARTHROPLASTYCOMPUTED-TOMOGRAPHYREDUCTION SOFTWAREHIP PROSTHESESIMAGE QUALITYOUTCOMES

식별자

Scopus EID
2-s2.0-85091117668
WoS UID
000585834300005