Evaluation of the Attenuation Rate for Clinical Application of a Flexible Skin Dosimeter in Radiotherapy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q4Scopus Q3
- 저널
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY77(11) · pp.1044 · 2020
- 피인용
- Web of Science 0Scopus 0KCI 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 0.535
- ISSN
- 0374-4884
저자
- Han, Moo-Jae제1저자Department of Radiation Oncology, College of Medicine, Inje University, Busan, 47392, Korea
- Yang, Seung-WooDepartment of Radiation Oncology, College of Medicine, Inje University, Busan, 47392, Korea
- Shin, Yo-HanDepartment of Radiation Oncology, College of Medicine, Inje University, Busan, 47392, Korea
- Bae, Sang-IlDepartments of Radiation Oncology, Dongnam Institute of Radiological & Medical Sciences, Busan, 46033, Korea
- Moon, Young-MinDepartments of Radiation Oncology, Dongnam Institute of Radiological & Medical Sciences, Busan, 46033, Korea
- Jeon, WanDepartments of Radiation Oncology, Dongnam Institute of Radiological & Medical Sciences, Busan, 46033, Korea
- Yu, To-SolDepartments of Radiation Oncology, Dongnam Institute of Radiological & Medical Sciences, Busan, 46033, Korea
- Kang, Jin-KyuDepartments of Radiation Oncology, Dongnam Institute of Radiological & Medical Sciences, Busan, 46033, Korea
- Kim, Jin-Young교신저자Departments of Radiation Oncology, Dongnam Institute of Radiological & Medical Sciences, Busan, 46033, Korea
- 허승욱Research Institute for Convergence of Biomedical Science and Technology, Yangsan Hospital, Pusan National University, Yangsan, 50615, Korea
- Park, Sung-KwangDepartment of Radiation Oncology, Busan Paik Hospital, Inje University, Busan, 47392, Korea
- Rah, Jeong-EunDepartment of Radiation Oncology, Myongji Hospital, Hanyang University College of Medicine, Goyang, 10475, Korea
- Chung, Jin BeomDepartment of Radiation Oncology, Seoul National University Bundang Hospital, Bundang, Seoul, 13620, Korea
초록
During radiotherapy, some patients owing to the variability in skin sensitivities, may experience adverse skin reactions for doses at which other patients are asymptomatic. Hence, when abnormal symptoms appear on a patient's skin, the etiology should be verified. Accordingly, a surface dosimeter on the skin can help ascertain whether accurate doses are irradiated. Furthermore, surface doses are measured in the field junction gaps during craniospinal irradiation or during large-area radiotherapy to avoid adverse reactions due to cumulative skin doses from multiple beams. However, the point dose measurement errors of surface dosimeters exceed approximately 10% and have low-positional accuracies because the attachment sites are approximated with the help of the naked eye. Moreover, accurate information on field junction gaps cannot be obtained. Therefore, in clinical practice, a flexible array dosimeter is required as it can measure the dose distribution on the body surface by adapting its shape to the body curvatures. In this study, we implemented a flexible array dosimeter and, based on its constituent materials, evaluated the attenuation rate associated with its use. A polyester (PET) film was used as the underlying substrate. HgI2 and PbI2 photoconductors were used for their good performances in films. Furthermore, the measurement accuracy was verified through comparisons with Monte Carlo simulation outcomes. The resulting PET film had an attenuation rate of 2.22% at a 50-mu m thickness. At the minimum material thickness of 25 mu m, the attenuation rates for HgI2 and PbI2 were 4.69% and 5.72%, respectively. Further research is needed to fabricate HgI2-based digital skin dosimeters with a thickness under 25 mu m. Radiation detection and pixel resolution should be evaluated to accurately confirm the field junction gap.
키워드
Attenuation rateSurface doseMonte Carlo simulationRadiotherapyCRANIOSPINAL IRRADIATIONTHICKNESS