본문 바로가기

Facial Fabrication and Characterization of Novel Ag/AgCl Chloride Ion Sensor Based on Gel-Type Electrolyte

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q2
저널
FRONTIERS IN CHEMISTRY8 · 2020
피인용
Web of Science 5Scopus 6
FWCI (Scopus)
0
JCR IF
JCR 2019 3.693
ISSN
2296-2646

저자

  1. Kim, Seil제1저자Department of Electrochemistry, Korea Institute of Materials Science, Changwon, South Korea
  2. 박광렬School of Materials Science and Engineering, Pusan National University, Busan, South Korea
  3. 안홍주School of Materials Science and Engineering, Pusan National University, Busan, South Korea
  4. Yoo, Bung UkDepartment of Electrochemistry, Korea Institute of Materials Science, Changwon, South Korea
  5. Song, In-HyuckDepartment of Engineering Ceramic, Korea Institute of Materials Science, Changwon, South Korea
  6. Lee, Kyu-HwanDepartment of Electrochemistry, Korea Institute of Materials Science, Changwon, South Korea
  7. 김광호교신저자School of Materials Science and Engineering, Pusan National University, Busan, South Korea
  8. Lim, Jae-Hong교신저자Department of Materials Science and Engineering, Gachon University, Seongnam, South Korea
  9. Lee, Joo-Yul교신저자Department of Electrochemistry, Korea Institute of Materials Science, Changwon, South Korea

초록

In this study, a novel chloride ion (Cl-) sensor based on Ag wire coated with an AgCl layer was fabricated using a gel-type internal electrolyte and a diatomite ceramic membrane, which played an important role in preventing electrolyte leakage from the ion-selective electrode. The sensing performance, including reversibility, response, recovery time, low detection limit, and the long-term stability, was systemically investigated in electrolytes with different Cl- contents. The as-fabricated Cl- sensor could detect Cl- from 1 to 500 mM KCl solution with good linearity. The best response and recovery time obtained for the optimized sensor were 0.5 and 0.1 s, respectively, for 10 mM KCl solution. An exposure period of over 60 days was used to evaluate the stability of the Cl- sensor in KCl solution. A relative error of 2% was observed between the initial and final response potentials. Further, a wireless sensing system based on Arduino was also investigated to measure the response potential of Cl- in an electrolyte. The sensor exhibited high reliability with a low standard error of measurement. This type of sensor is crucial for fabricating wireless Cl- sensors for applications in reinforced concrete structures along with favorable performances.

키워드

chloride ion sensorAgAgCl electrodediatomite ceramic membranegel-type internal electrolytereinforced concrete structurechronopotentiometryDISPROPORTIONATIONNANOCUBESCONCRETEAg/AgCl electrode