본문 바로가기

Electrochemical detection of interleukin-8 in human saliva using a polyenzyme label based on diaphorase and neutravidin

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 14Scopus 16
FWCI (Scopus)
1.11
JCR IF
JCR 2020 7.46
ISSN
0925-4005

저자

  1. 바티아 아만제1저자Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
  2. 나희삼Department of Oral Microbiology, School of Dentistry, Pusan National University, Gyeongsangnam-do 50612, Korea
  3. 포누사미 난다쿠마르Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
  4. Yu, ByeongjunDepartment of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea
  5. Jon, SangyongDepartment of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Korea
  6. 정진교신저자Department of Oral Microbiology, School of Dentistry, Pusan National University, Gyeongsangnam-do 50612, Korea
  7. 양해식Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea

초록

Polyenzymes have been commonly employed as catalytic labels to obtain high signal amplification in immunoassays, but they are mainly constructed using horseradish peroxidase that requires the use of H2O2, whose storage is difficult. Here, we present a new polyenzyme label based on diaphorase (DI), a dehydrogenase redox enzyme with high catalytic activity and long-term stability. The polyenzyme label is constructed using a complex of a biotinylated DI and an avidin analog. Among the five commercially available DIs, the one that shows the highest signal amplification using electrochemical-enzymatic redox cycling involving an electron mediator, a DI, and NADH is chosen. Among the three avidin analogs (avidin, neutravidin, and streptavidin), neutravidin provides the lowest nonspecific binding of the polyenzyme label. The polyenzyme label shows higher signal amplification and lower nonspecific binding than a single enzyme label of DI. Comparative studies reveal that the detection limit for the detection of interleukin-8 (IL-8) in saliva using the polyenzyme label (similar to 1 pg/mL) is one order of magnitude lower than that using a single enzyme label (similar to 10 pg/mL). IL-8 concentrations measured in clinical saliva samples agree well with those measured using a conventional microplate immunoassay. Thus, the polyenzyme label can be applied for the noninvasive detection of other clinically relevant proteins in saliva.

키워드

Polyenzyme labelElectrochemical detectionDiaphoraseNeutravidinInterleukin-8DT-DIAPHORASEIMMUNOSENSORAMPLIFICATIONNANOPARTICLESIMMUNOASSAYSCYTOKINESCOMPLEXSYSTEMS

식별자

Scopus EID
2-s2.0-85092322985
WoS UID
000582806300062