Evaluation of the electrical properties of a lead (II) iodide based-dosimeter based on mechanical flexibility for surface dose measurements in radiotherapy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- JOURNAL OF INSTRUMENTATION15(8) · 2020
- 피인용
- Web of Science 1Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 1.454
- ISSN
- 1748-0221
저자
- Han, M. J.제1저자Department of Radiation Oncology, College of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea
- Yang, S. W.Department of Radiation Oncology, College of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea
- 정재훈Department of Research Institute for Convergence of Biomedical Science and Technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
- 허성진Department of Research Institute for Convergence of Biomedical Science and Technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
- Kim, J. Y.Departments of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangsan-eup, Gijang-gun, Busan, Republic of Korea
- Cho, S. J.Department of Radiation Oncology, Ehwa Woman's University Mokdong Hospital, 1071, Anyangcheon-ro, Yangcheon-gu, Seoul, Republic of Korea
- Cho, H. L.Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea
- Park, S. K.교신저자Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea
초록
In radiotherapy, point doses via surface dose measurement are confirmed using a dosimeter attached to the patient's skin. This results in an error margin of about 11.8% or higher because the attachment site is visually confirmed. Thus, a digital flexible array dosimeter that can analyse body surface area is needed. Here, a lead (II) iodide (PbI2)-based unit cell flexible dosimeter was developed, and its electrical properties were evaluated based on its mechanical flexibility by assessing its reproducibility and linearity for bending. The relative standard deviation (RSD) for measurement by the sensor over 10,000 cycles was 1.74% and 2.21% at 6 MV and 15 MV, respectively, which is higher than RSD's evaluation criterion (<1.5%). Although the linearity of measurement by the sensor over 10,000 cycles met the evaluation criteria of a coefficient of determination R-2 > 0.9990, the sensitivity at 15 MV was lower than that at 6 MV. The results of this study confirm the applicability and usefulness of the PbI2-based flexible dosimeter in radiation measurements.
키워드
Dosimetry concepts and apparatusMaterials for solid-state detectorsRadiation damage to detector materials (solid state)Radiotherapy conceptsRadiationdamage to detector materials (solid state)
식별자
- Scopus EID
- 2-s2.0-85090900662
- WoS UID
- 000577269100021



로그인
연구물 목록으로