본문 바로가기

Chlorhexidine bathing of the exposed circuits in extracorporeal membrane oxygenation: an uncontrolled before-and-after study

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
CRITICAL CARE24(1) · 2020
피인용
Web of Science 17Scopus 21
FWCI (Scopus)
0
JCR IF
JCR 2019 6.407
ISSN
1364-8535

저자

  1. 여혜주제1저자Department of Pulmonology and Critical Care Medicine, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital Geumo-ro 20, Beomeo-ri, Mulgeum-eup Yangsan-si, Gyeongsangnam-do 626-770 Republic of Korea
  2. 김도형Department of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital Yangsan-si South Korea
  3. 하미향Interdisciplinary program of Genomic Science, Pusan National University Yangsan-si South Korea
  4. 제형곤Department of Thoracic and Cardiovascular Surgery, Pusan National University Yangsan Hospital Yangsan-si South Korea
  5. 김정수Division of cardiology, Department of Internal Medicine, Pusan National University Yangsan Hospital Yangsan-si South Korea
  6. 조우현교신저자Department of Pulmonology and Critical Care Medicine, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital Geumo-ro 20, Beomeo-ri, Mulgeum-eup Yangsan-si, Gyeongsangnam-do 626-770 Republic of Korea

초록

BackgroundAlthough the prevention of extracorporeal membrane oxygenation (ECMO) catheter-related infection is crucial, scientific evidence regarding best practices are still lacking.MethodsWe conducted an uncontrolled before-and-after study to test whether the introduction of disinfection with 2% chlorhexidine gluconate (CHG) and 70% isopropyl alcohol (IPA) of the exposed circuits and hub in patients treated with ECMO would affect the rate of blood stream infection (BSI) and microbial colonization of the ECMO catheter. We compared the microbiological and clinical data before and after the intervention.ResultsA total of 1740 ECMO catheter days in 192 patients were studied. These were divided into 855 ECMO catheter days in 96 patients before and 885 ECMO catheter days in 96 patients during the intervention. The rates of BSI were significantly decreased during the intervention period at 11.7/1000 ECMO catheter days before vs. 2.3/1000 ECMO catheter days during (difference 9.4, 95% confidence interval (CI) 1.5-17.3, p=0.019). Furthermore, the colonization of the ECMO catheter was similarly significantly reduced during the intervention period at 10.5/1000 ECMO catheter days before vs. 2.3/1000 ECMO catheter days during intervention (difference 8.3, 95% CI 0.7-15.8, p=0.032). Hospital mortality (41.7% vs. 24%, p=0.009) and sepsis-related death (17.7% vs. 6.3%, p=0.014) were also significantly decreased during intervention.ConclusionExtensive disinfection of exposed ECMO circuits and hub with 2% CHG/IPA was associated with a reduction in both BSI and microbial colonization of ECMO catheters. A further randomized controlled study is required to verify these results.Trial registrationKCT 0004431

키워드

Chlorhexidine disinfectionECMOCatheterInfectionMortalityBLOOD-STREAM INFECTIONSCOLONIZATIONEPIDEMIOLOGYPATHOGENESISGLUCONATERESISTANTIMPACT

식별자

Scopus EID
2-s2.0-85092395904
WoS UID
000578418700002