Design of Super Twisting Sliding Mode Controller for a Three-Phase Grid-connected Photovoltaic System under Normal and Abnormal Conditions
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q1
- 저널
- ENERGIES13(15) · 2020
- 피인용
- Web of Science 32Scopus 42
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 2.702
- ISSN
- 1996-1073
저자
- 젭 캄란제1저자School of Electrical Engineering, Pusan National University, San 30, ChangJeon 2 Dong, Pusandaehak-ro 63 beon-gil 2, Geumjeong-gu, Busan 46241, Korea
- Busarello, Tiago Davi CuriDepartment of Control, Automation and Computing Engineering, Federal University of Santa Catarina, Blumenau 89036-256, Brazil
- 이슬람 사이프 울School of Electrical Engineering, Pusan National University, San 30, ChangJeon 2 Dong, Pusandaehak-ro 63 beon-gil 2, Geumjeong-gu, Busan 46241, Korea
- 우딘 와카르School of Electrical Engineering, Pusan National University, San 30, ChangJeon 2 Dong, Pusandaehak-ro 63 beon-gil 2, Geumjeong-gu, Busan 46241, Korea
- 쿠마라 벵카타 구루 라가벵드라School of Electrical Engineering, Pusan National University, San 30, ChangJeon 2 Dong, Pusandaehak-ro 63 beon-gil 2, Geumjeong-gu, Busan 46241, Korea
- Khan, Muhammad AdilDepartment of Engineering, Air University, Islamabad 44000, Pakistan
- 김희제교신저자School of Electrical Engineering, Pusan National University, San 30, ChangJeon 2 Dong, Pusandaehak-ro 63 beon-gil 2, Geumjeong-gu, Busan 46241, Korea
초록
The novelty behind the research in this paper is to investigate the Super Twisting Sliding Mode Controller (ST-SMC) for efficiently injecting both active and reactive power under normal and abnormal operating conditions for a three-phase grid-connected photovoltaic (PV) system. The ST-SMC is aimed to inject sinusoidal current to the grid with low Total Harmonic Distortion (THD), to avoid chattering with easy real implementation, and to enhance the quality of disturbance rejection and sensitivity to parameter variation. The test under normal conditions includes initialization, steady state behavior, dynamic behavior, and interrupting the injection of acting and reactive power while the abnormal conditions consists of voltage sag, voltage swell, frequency variation, DC-link variation, and inclusion of 5th harmonics, etc. The phase lock loop used for synchronization is based on a synchronous reference frame that works well under distorted grids and nonideal. Automatic code is generated in PSIM 9.1 for hardware implementation in the DSP board TMS32F28335 from Texas Instruments while code composer studio 6.2.0 is used for debugging. The real time testing is executed using Typhoon Hardware in Loop (HIL) 402 device on the DSP board. The results authenticate the fastness, effectiveness, and robustness for both steady state and dynamic behavior under various scenarios of the designed controller.
키워드
Super Twisting AlgorithmSliding Mode Controllertotal harmonic distortiongrid-connected photovoltaic systemTyphoon HILFED INDUCTION GENERATORNEURAL-NETWORKTRACKING TECHNIQUESPREDICTIVE CONTROLCURRENT HARMONICSPOWER-CONTROLPV SYSTEMINVERTERIMPLEMENTATIONMITIGATION
식별자
- Scopus EID
- 2-s2.0-85088880981
- WoS UID
- 000559074900001



로그인
연구물 목록으로