Buckling Resistance of Various Nickel-Titanium Glide Path Preparation Instruments in Dynamic or Static Mode
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- JOURNAL OF ENDODONTICS46(8) · pp.1125 · 2020
- 피인용
- Web of Science 4Scopus 7
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 3.118
- ISSN
- 0099-2399
저자
- Ha, Jung-Hong제1저자Department of Conservative Dentistry, School of Dentistry, Kyungpook National University, Daegu, Korea
- 곽상원Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan, Korea
- Versluis, AntheunisDepartment of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, TN, USA
- 김현철교신저자Department of Conservative Dentistry, School of Dentistry, Dental Research Institute, Pusan National University, Yangsan, Korea
초록
Introduction: The aim of this study was to compare the buckling resistance of nickel-titanium (NiTi) instruments for glide path preparation depending on the test mode (static vs dynamic). Methods: The conventional PathFile (PF; Dentsply Sirona, Ballaigues, Switzerland) and heattreated ProGlider (PG, Dentsply Sirona) and WaveOne Gold Glider (WG, Dentsply Sirona) were evaluated. The instrument tips were placed in a small dimple prepared in an aluminum cube in a customized device. The file was then pushed in the axial direction at a 1.0-mm/s crosshead speed with rotation (dynamic mode) or without rotation (static mode). The dynamic mode of WG used its dedicated reciprocating rotation, whereas the others were rotated continuously at 300 rpm. The axial load and lateral buckling displacement were simultaneously measured. Data were analyzed statistically using 2-way analysis of variance (P=.05). Results: The buckling resistance in the dynamic mode was higher than in the static mode for PG and WG(P<.05), whereas PF was not influenced by test modes (P>.05). In the dynamic mode, the PG required the highest buckling load followed by PF and WG (P<.05). In the static mode, the WG showed the lowest load (P<.05). The dynamic mode showed significantly more upper level lateral buckling displacement than in the static mode (P<.05). Conclusions: When the glide path preparation instruments moved in the dynamic mode as in clinical situations, the buckling resistance of the heat-treated NiTi glide path instruments was higher than in the static condition. The heat-treated instruments may have better buckling resistance than the conventional NiTi instrument in clinical situations.
키워드
Buckling resistancedynamicglide pathnickel-titanium rotary filerotationstaticMECHANICAL-BEHAVIORROTARY
식별자
- Scopus EID
- 2-s2.0-85087406752
- WoS UID
- 000553374700016



로그인
연구물 목록으로