본문 바로가기

A comprehensive mass balance model of a 550 MWe ultra- supercritical CFB boiler with internal circulation

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ENERGY206 · 2020
피인용
Web of Science 26Scopus 30
FWCI (Scopus)
0
JCR IF
JCR 2019 6.082
ISSN
0360-5442

저자

  1. 이동방제1저자School of Mechanical Engineering, Pusan CFBC Research Center, Pusan National University, Republic of Korea
  2. Ke, XiweiKey Laboratory for Thermal Science and Power Engineering of Ministry Education, Department of Energy and Power Engineering, Tsinghua University, China
  3. Zhang, ManKey Laboratory for Thermal Science and Power Engineering of Ministry Education, Department of Energy and Power Engineering, Tsinghua University, China
  4. Yang, HairuiKey Laboratory for Thermal Science and Power Engineering of Ministry Education, Department of Energy and Power Engineering, Tsinghua University, China
  5. Jung, SungmookSamcheok Thermal Power Plant Division, Korea Southern Power Company (KOSPO), Republic of Korea
  6. 안석기Samcheok Thermal Power Plant Division, Korea Southern Power Company (KOSPO), Republic of Korea
  7. 전충환교신저자School of Mechanical Engineering, Pusan CFBC Research Center, Pusan National University, Republic of Korea

초록

The world's first 550 MWe ultra-supercritical circulating fluidized bed (CFB) boiler designed with integrated recycle heat exchangers (INTREX) commenced operation in 2016. One of the distinguishing features of the INTREX is the internal circulation opening (ICO) that allows the particles in the furnace to flow into the INTREX to enhance the bed-to-tube heat transfer, while the heat transfer is strongly affected by both the mass flow rate of internal circulation and (m) over dot(ic) particle size in the INTREX, i.e., the mass balance of the INTREX. In the present study, we established a comprehensive one-dimensional model to investigate the mass balance of the boiler including the internal circulation. The coefficient of rebound eta(ICO) was adopted to simulate particle behavior during internal circulation. The experimentally acquired parameters of ash formation and attrition of the coal ash were adopted in the model. The size of INTREX ash obtained from the field test on the 550 MWe boiler was used to determine the value of eta(ICO). The model results were verified with field tests, and they showed reasonable validity. The model results of the linear correlation between (m)(over dotic) and bed pressure displayed good agreement with those from the field tests. (C) 2020 Elsevier Ltd. All rights reserved.

키워드

Mass balanceCFB BoilerInternal circulationIntegrated recycle heat exchangerFLUIDIZED-BED COMBUSTIONGAS-SOLID FLOWHEAT-TRANSFERHORIZONTAL TUBEATTRITION CHARACTERISTICSPERFORMANCETECHNOLOGYEXCHANGERSSIMULATIONUNIFORMITY

식별자

Scopus EID
2-s2.0-85087091615
WoS UID
000552898300002