Evaluation of attenuation rate error for optimisation of skin dosimeter in electron beam therapy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- JOURNAL OF INSTRUMENTATION15(7) · 2020
- 피인용
- Web of Science 0Scopus 0
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 1.454
- ISSN
- 1748-0221
저자
- Han, M. J.제1저자Department of Radiation Oncology, Collage of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea
- Yang, S. W.Department of Radiation Oncology, Collage of Medicine, Inje University, Bokji-ro 75, Busan, Republic of Korea
- Bae, S. I.Department of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangsan-eup, Gijang-gun, Busan, Republic of Korea
- Moon, Y. M.Department of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangsan-eup, Gijang-gun, Busan, Republic of Korea
- 허승욱Department of Research Institute for Convergence of Biomedical Science and Technology, Yangsan Hospital, Pusan National University, 20, Geumo-ro, Mulgeum-eup, Yangsan-si, Gyeongsangnam-do, Republic of Korea
- Choi, C. W.Department of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangsan-eup, Gijang-gun, Busan, Republic of Korea
- Park, S. K.Department of Radiation Oncology, Busan Paik Hospital, Inje University, Bokji-ro 75, Busan, Republic of Korea
- Kim, J. Y.교신저자Department of Radiation Oncology, Dongnam Institute of Radiological and Medical Sciences, 40, Jwadong-gil, Jangsan-eup, Gijang-gun, Busan, Republic of Korea
초록
In the field of radiation therapy, the need for a flexible dosimeter that can be applied on the flexor surface for precise measurement of the surface dose is increasing. In particular, electron beam therapy has a shorter treatment depth than photon beam therapy; therefore, the surface dose must be measured accurately. This study investigates attenuation errors in a dosimeter. We demonstrated that the attenuation error depends on the thickness of the flexible functional materials, and it can serve as fundamental research for creating a flexible dosimeter that can be applied on the human body. The results indicated that the maximum attenuation error of a polyethylene terephthalate film with a thickness of 75 mu m was 0.40% and 0.027% at 6 MeV and 9 MeV, respectively. Moreover, when using HgI2 and PbI2 as photoconductor materials, the maximum attenuation errors at 6 MeV were 1.35% and 1.67%, respectively. This study provides fundamental insights into dose errors by using a surface dosimeter and error variables to produce a surface dosimeter. Further, because the study investigates flexible materials, the findings can be extended to various applications in the field of radiation therapy.