본문 바로가기

MBF 20으로 브레이징한 STS304 콤팩트 열교환기 접합부의 미세조직에 미치는 가열속도의 영향

Effect of Heating Rates on Microstructures in Brazing Joints of STS304 Compact Heat Exchanger using MBF 20

문서 유형
연구출판물 · 학술지 논문
등재
KCI
저널
대한용접접합학회지34(2) · pp.46 · 2016
피인용
KCI 1
ISSN
2466-2232

저자

  1. 김준태제1저자부산대학교 융합학부
  2. 허회준부산대학교 재료공학과
  3. 김현준동화엔텍
  4. 강정윤교신저자부산대학교

초록

Effect of heating rate on microstructure of brazed joints with STS 304 Printed Circuit Heat Exchanger(PCHE),which was manufactured as large-scale(1170(L) × 520(W) × 100(T), mm), have been studied to comparebonding phenomenon. The specimens using MBF 20 was bonded at 1080℃ for 1hr with 0.38℃/min and20℃/min heating rate, respectively. In case of a heating rate of 20℃/min, overflow of filler metal was observedat the edge of a brazed joints showing the height of filler metal was decreased from 100㎛ to 68㎛. At thecenter of the joints, CrB and high Ni contents of γ-Ni was existed. For the joints brazed at a heating rateof 0.38℃/min, the height of filler was decreased from 100㎛ to 86㎛ showing the overflow of filler was notappeared. At the center of the joints, only γ-Ni was detected gradating the Ni contents from center. Thisphenomenon was driven from a diffusion amount of Boron in filler metal. With a fast heating rate 20℃/min,diffusion amount of B was so small that liquid state of filler metal and base metal were reacted. But, fora slow heating rate 0.38℃/min, solid state of filler metal due to low diffusion amount of B reacted with basemetal as a solid diffusion bonding.

키워드

PCHE (Pring cicuit heat exchanger)BrazingMBF 20Boron diffusionMicrostructure

식별자

KCI
ART002101583