MBF 20으로 브레이징한 STS304 콤팩트 열교환기 접합부의 미세조직에 미치는 가열속도의 영향
Effect of Heating Rates on Microstructures in Brazing Joints of STS304 Compact Heat Exchanger using MBF 20
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널
- 대한용접접합학회지34(2) · pp.46 · 2016
- 피인용
- KCI 1
- ISSN
- 2466-2232
저자
초록
Effect of heating rate on microstructure of brazed joints with STS 304 Printed Circuit Heat Exchanger(PCHE),which was manufactured as large-scale(1170(L) × 520(W) × 100(T), mm), have been studied to comparebonding phenomenon. The specimens using MBF 20 was bonded at 1080℃ for 1hr with 0.38℃/min and20℃/min heating rate, respectively. In case of a heating rate of 20℃/min, overflow of filler metal was observedat the edge of a brazed joints showing the height of filler metal was decreased from 100㎛ to 68㎛. At thecenter of the joints, CrB and high Ni contents of γ-Ni was existed. For the joints brazed at a heating rateof 0.38℃/min, the height of filler was decreased from 100㎛ to 86㎛ showing the overflow of filler was notappeared. At the center of the joints, only γ-Ni was detected gradating the Ni contents from center. Thisphenomenon was driven from a diffusion amount of Boron in filler metal. With a fast heating rate 20℃/min,diffusion amount of B was so small that liquid state of filler metal and base metal were reacted. But, fora slow heating rate 0.38℃/min, solid state of filler metal due to low diffusion amount of B reacted with basemetal as a solid diffusion bonding.
키워드
PCHE (Pring cicuit heat exchanger)BrazingMBF 20Boron diffusionMicrostructure
식별자
- KCI
- ART002101583