본문 바로가기

Effect of pressure and temperature on bulk micro defect and denuded zone in nitrogen ambient furnace

문서 유형
연구출판물 · 학술지 논문
등재
KCI
저널
한국결정성장학회지26(3) · pp.121 · 2016
피인용
KCI 0
ISSN
1225-1429

저자

  1. 최영규제1저자부산대학교
  2. 정세영LG 실트론
  3. 심복철교신저자한양사이버대학교

초록

The effect of temperature and pressure in the nitrogen ambient furnace on bulk micro defect (BMD) and denuded zone (Dz) is experimentally investigated. It is found that as pressure increases, Dz depth increases with a small decrease of BMD density in the range of temperature, 100~300 o C. BMD density with hot isostatic pressure treatment (HIP) at temperature of 850 o C is higher than that without HIP while Dz depth is lower due to much higher BMD density. As the pressure increases, BMD density is increased and saturated to a critical value, and Dz depth increases even if BMD density is saturated. The concentration of nitrogen increases near the surface with increasing pressure, and the peak of the concentration moves closer to the surface. The nitrogen is gathered near the surface, and does not become in-diffusion to the bulk of the wafer. The silicon nitride layer near the surface prevents to inject the additional nitrogen into the bulk of the wafer across the layer. The nitrogen does not affect the formation of BMD. On the other hand, the oxygen is moved into the bulk of the wafer by increasing pressure. Dz depth from the surface is extended into the bulk because the nuclei of BMD move into the bulk of the wafer.

키워드

Bulk micro defectDenuded zoneNitrogen ambient furnaceSilicon wafer

식별자

KCI
ART002118367