Comparison of noise-optimized linearly blended images and noise-optimized virtual monoenergetic images evaluated by dual-source, dual-energy CT in cardiac vein assessment
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- ACTA RADIOLOGICA62(5) · pp.594 · 2021
- 피인용
- Web of Science 3Scopus 3
- FWCI (Scopus)
- 0.32
- JCR IF
- JCR 2020 1.99
- ISSN
- 0284-1851
저자
- 김경민제1저자Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
- 추기석교신저자Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
- 김진혁Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
- 황재연Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
- 박찬규Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Republic of Korea
- 이지원ADepartment of Radiology, Pusan National University Hospital, Busan, Republic of Korea
- Lim, Soo JinDepartment of Cardiology, Kim Hae Kangil Hospital, Gimhae, Republic of Korea
초록
Background The coronary venous system is frequently used as an entry route to the heart and treatment modalities for many cardiac diseases and many procedures. Consequently, evaluation of the coronary venous system and understanding cardiac vein anatomy is crucial. Purpose To determine the optimal image set in a comparison of noise-optimized linearly blended images (F_0.6) and noise-optimized virtual monoenergetic images (VMI+) evaluated by dual-energy computed tomography (DECT) for cardiac vein assessment. Material and Methods Thirty-four patients (mean age 58.2 +/- 14.2 years) who underwent DECT due to chest pain were enrolled. Images were post-processed with the F_0.6, and VMI+ algorithms at energy levels in the range of 40-100 keV in 10-keV increments. Enhancement (HU), noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively measured at two points in the great cardiac vein by consensus of two radiologists. Two blinded observers evaluated the subjective image quality of the great cardiac vein on a 4-point scale. Results HU, noise, and SNR peaked at 40 keV VMI+ (P < 0.05) among 50-100 keV VMI+. CNR peaked at 100 keV VMI+; however, there were no significant differences compared to CNR images processed at 40-90 keV VMI+. HU and noise were significantly higher in 40 keV VMI+ than F_0.6 images; however, both SNR and CNR were significantly higher in F_0.6 images. An assessment of subjective vein delineation revealed that F_0.6 images had the highest scores Conclusion F_0.6 images were superior to VMI+ and provided the optimal image set for cardiac vein assessment.