본문 바로가기

Nanochannel-driven rapid capture of sub-nanogram level biomarkers for painless preeclampsia diagnosis

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 38Scopus 40
FWCI (Scopus)
0
JCR IF
JCR 2019 10.257
ISSN
0956-5663

저자

  1. 강예은제1저자Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea
  2. 성금용Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea
  3. 임상구Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea
  4. 이예찬Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea
  5. 안성민Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea
  6. 김승철Department of Obstetrics and Gynecology, Pusan National University School of Medicine, Busan 49241, Republic of Korea
  7. 김규정Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Republic of Korea
  8. 안범수Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea
  9. 이규섭Department of Obstetrics and Gynecology, Pusan National University School of Medicine, Busan 49241, Republic of Korea
  10. 양승윤교신저자Department of Biomaterials Science, Pusan National University, Miryang 50463, Republic of Korea

초록

Preeclampsia (PE) is a pregnancy-specific hypertensive syndrome recognized as the leading cause of maternal and fetal morbidity and mortality worldwide. Painful blood-collection procedures or low accuracy of non-invasive approaches require faster, patient-friendly, and more sensitive diagnostic technologies. Here we report a painless, highly sensitive detection platform using nanoporous microneedles (nMNs) that enables rapid capture of biomarkers present at sub-nanogram levels. The highly porous nanostructures on the nMN surface were prepared by anodization of aluminum MN and then functionalized by immobilization of capture antibodies to detect target biomarkers based on an immunoassay method. The immuno-functionalized nMN array demonstrated rapid capture of an estrogen (E2) biomarker for PE following a 1-min incubation and exhibited a concentration-dependent change in fluorescence intensity over the E2 range of 0.5 ng mL(-1) to 1000 ng mL(-1) after treatment with fluorescence-detection antibodies. Remarkably, the nMN patch selectively detected sub-nanogram-levels of E2 in subcutaneous interstitial fluid from rats with increased diagnostic accuracy as compared with commercial immunoassay kits. This bio-functionalized nMN platform showed improved biosensing capability for multiple PE-related biomarkers, including hormones and proteins. Furthermore, this painless method demonstrated efficacy as a point-of-need diagnostic platform using portable smartphone-based fluorescence microscope to obtain fluorescence images of biomarker-captured nMN arrays.

키워드

BiosensorPreeclampsiaMicroneedleImmunoassayPainless diagnosisIMMUNOASSAYARRAYWOMENSKINPATHOGENESISANODIZATIONANDROGENSPREGNANCYANALYTESPLACENTA

식별자

Scopus EID
2-s2.0-85084863345
WoS UID
000541155200012