본문 바로가기

In silico evaluation of the peripheral and inner seals in complete denture master impressions using a custom-developed 3D software

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
CLINICAL ORAL INVESTIGATIONS25(1) · pp.125 · 2021
피인용
Web of Science 8Scopus 13
FWCI (Scopus)
0.73
JCR IF
JCR 2020 3.573
ISSN
1432-6981

저자

  1. Kalberer, Nicole제1저자Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
  2. Chebib, NajlaDivision of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
  3. Wachter, WolfgangIvoclar Vivadent AG, Schaan, Liechtenstein
  4. 이현종Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan, South Korea
  5. Müller, FraukeDivision of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
  6. Srinivasan, Murali교신저자Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland

초록

Objectives Despite the complexity of the edentulous anatomy, little evidence exists as to what impression techniques and materials should be employed for an optimal result. The aim of this in silico study was to evaluate the trueness of peripheral and inner seals of different edentulous jaw impressions. Materials and methods Twelve maxillary edentulous participants (male = 8, female = 4; age 68.5 +/- 11.7 years) participated in this study. Four different impression materials and techniques, irreversible hydrocolloid (Alginate; Blueprint X-Creme, Dentsply Sirona, PA, USA), polyvinyl siloxane impression (PVS; Aquasil Ultra+ Medium, Dentsply Sirona, PA, USA), and subsequently modified with ZnOE (PVSM) and an optical impression (Optical; 3Shape A/S, Copenhagen, Denmark), were tested against a control impression: low-fusing impression compound border molding (Kerr Corp., CA, USA) followed by a ZnOE impression (ZnOE; SS White impression paste, S.S. White Group, Gloucester, England). All impressions were scanned and analyzed using a custom-built 3D comparison software analyzing the vertical and horizontal trueness. Results The vertical discrepancy (peripheral seal) of the impression surface was significantly more true for PVSM than Alginate (p = 0.001), PVS (p = 0.019), and Optical groups (p < 0.001). Where the horizontal discrepancy (inner seal) was compared, the impression surface was more true for PVSM than Alginate (p < 0.001) and Optical (p < 0.001). PVS group was also significantly more true than Optical (p = 0.015). Conclusion Impression techniques and materials may significantly influence the peripheral and inner seal of an edentulous jaw impression.

키워드

Complete denture master impressionComplete denture impression techniquesTruenessPeripheral borderInner sealOptical edentulous impressionJ PROSTHET DENTNEUTRAL ZONEPROSTHODONTICS

식별자

Scopus EID
2-s2.0-85085899838
WoS UID
000537380800004