본문 바로가기

Ultrasensitive detection of hydrogen peroxide and dopamine using copolymer-grafted metal-organic framework based electrochemical sensor

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
ANALYTICA CHIMICA ACTA1118 · pp.26 · 2020
피인용
Web of Science 76Scopus 83
FWCI (Scopus)
0
JCR IF
JCR 2019 5.977
ISSN
0003-2670

저자

  1. 샤밈 아흐메드 히라제1저자Department of Chemistry, Pusan National University, Busan, 46241, South Korea
  2. NALLAL MUTHUCHAMYDepartment of Chemistry, Pusan National University, Busan, 46241, South Korea
  3. Rajendran, KarkuzhaliDepartment of Industrial Chemistry, Alagappa University, Karaikudi-630003, Tamil Nadu, India
  4. 송세환Department of Physics, Pusan National University, Busan, 46241, South Korea
  5. 박성균Department of Physics, Pusan National University, Busan, 46241, South Korea
  6. 이제명Department of Naval Architecture, Pusan National University, Busan, 46241, South Korea
  7. Joo, Sang HoonDepartment of Energy Engineering and School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan, 44919, South Korea
  8. 박강현교신저자Department of Chemistry, Pusan National University, Busan, 46241, South Korea

초록

We reported the synthesis of a copolymer- and metal-organic framework-based electrochemical sensor, UiO-66-NH2@P(ANI-co-ANA) using the polymerization method for the highly sensitive and selective detection of hydrogen peroxide (H2O2) and dopamine (DA). The as-synthesized material was characterized via Fourier transform infrared spectroscopy, X-ray diffraction analysis, scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and thermogravimetric analysis. The electrochemical characteristics of the proposed sensor were evaluated via impedance spectroscopy and cyclic voltammetry (CV). The electrochemical oxidation of DA and the reduction of H2O2 were determined via CV, square-wave voltammetry, and chronoamperometric techniques. The fabricated sensor exhibited a wide linear range of 25-500 mu M, with a sensitivity of 1396.1 mu A mu M-1 cm(-2) and a limit of detection of 0.6 mM, for the electrochemical reduction of H2O2. Additionally, it exhibited a wide linear range of 10-110 mM, with a sensitivity of 1110.2 mu A mu M(-1)cm(-2) and a limit of detection of 0.3 mu M, for the electrochemical detection of DA. The practical utility of the fabricated sensor was evaluated via the detection of H2O2 in milk samples and DA in human urine samples. (C) 2020 Elsevier B.V. All rights reserved.

키워드

Metal-organic frameworkPolymerizationSensorDopamineHydrogen peroxideH2O2ELECTRODEFACILENANOPARTICLESFABRICATIONCOMPOSITESPLATFORMGLUCOSESAMPLESFLOW