Diagnostic Performance of F-18 Fluorodeoxyglucose Positron Emission Tomography or Positron Emission Tomography/Computed Tomography for Differentiation of Benign and Malignant Vertebral Compression Fractures: A Meta-Analysis
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- WORLD NEUROSURGERY137 · pp.E626 · 2020
- 피인용
- Web of Science 7Scopus 7
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 1.829
- ISSN
- 1878-8750
저자
- 김성장제1저자Department of Nuclear Medicine, BioMedical Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, and Department of Nuclear Medicine, College of Medicine, Pusan National University, Yangsan, Republic of Korea
- 이정섭교신저자Department of Orthopaedic Surgery, BioMedical Research Institute, Pusan National University Hospital, Pusan National University, Busan, Republic of Korea
초록
OBJECTIVE: The purpose of the present study was to investigate the diagnostic performance of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the differentiation of benign and malignant vertebral compression fractures (VCFxs) through a systematic review and meta-analysis. METHODS: MEDLINE via PubMed, Cochrane, Scopus, and Embase database, from the earliest available date of indexing through September 30, 2019, were searched for studies evaluating the diagnostic performance of F-18 FDG PET or PET/CT for the differentiation of malignant VCFxs. We determined the sensitivities and specificities across the studies, calculated the positive and negative likelihood ratios (LRD and LRL, respectively), and constructed summary receiver operating characteristic curves. RESULTS: For the 5 studies (274 patients), the pooled sensitivity was 0.96 (95% confidence interval [CI], 0.82-0.99) without heterogeneity (I-2, 50.6) and 0.77 (95% CI, 0.56-0.89) with heterogeneity (I-2, 76.1). LR syntheses gave an overall LRD of 4.1 (95% CI, 2.1-8.0) and LR- of 0.05 (95% CI, 0.01-0.23). The pooled diagnostic odds ratio (DOR) was 78 (95% CI, 19-316). The hierarchical summary receiver operating characteristic curve indicates that the areas under the curve was 0.94 (95% CI, 0.92-0.96). CONCLUSIONS: The results of the present meta-analysis have shown high sensitivity and moderate specificity for F-18 FDG PET and PET/CT for differentiation of malignant VCFxs. At present, the reported data regarding the use of F-18 FDG PET for differentiation of malignant VCFxs remain limited; thus, further large multicenter studies are necessary to substantiate the diagnostic accuracy of F-18 FDG PET for the differentiation of malignant VCFxs.
키워드
F-18 FDGMalignant fracturePET/CTVertebral fractureSYSTEMATIC REVIEWSTEST ACCURACYOSTEOPOROSISCOLLAPSERATIOBIAS
식별자
- Scopus EID
- 2-s2.0-85081938673
- WoS UID
- 000532726200024



로그인
연구물 목록으로