Is Mobile-Bearing Medial Unicompartmental Knee Arthroplasty Appropriate for Asian Patients With the Risk of Bearing Dislocation?
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- JOURNAL OF ARTHROPLASTY35(5) · pp.1222 · 2020
- 피인용
- Web of Science 17Scopus 23
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 3.709
- ISSN
- 0883-5403
저자
- 강석웅제1저자Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Republic of Korea
- Kim, Kyung-TaekDepartment of Orthopaedic Surgery, Dong-Eui Medical Center
- Hwang, Youn-SooDepartment of Orthopaedic Surgery, Dong-Eui Medical Center
- Park, Won-RoDepartment of Orthopaedic Surgery, Dong-Eui Medical Center
- Shin, Jong-KiDepartment of Orthopaedic Surgery, Dong-Eui Medical Center
- Song, Moo-Ho교신저자Department of Orthopaedic Surgery, Dong-Eui Medical Center
초록
Background: Mobile-bearing unicompartmental knee arthroplasty (UKA) is an attractive operation for medial unicompartmental knee arthritis, but unexpected bearing dislocation is a drawback. Bearing dislocation occurs more frequently in Asians, whose lifestyle involves deeper knee flexion than Westerners. This study investigated whether mobile-bearing medial UKA is appropriate for Asians by analyzing (1) the rate of bearing dislocation and (2) the results of patients with bearing dislocation. Methods: We retrospectively reviewed 531 consecutive mobile-bearing medial UKA in the previous 15 years, including 22 patients with bearing dislocation who had at least 2 years of follow-up. The entire patient cohort was divided into 2 groups: the symmetrical bearing (187 knees) and the anatomic bearing (344 knees) groups. In the anatomic bearing group, patients who underwent surgery using the conventional phase III (283 knees) vs the Microplasty (61 knees) instrumentation systems were compared. Results: The overall incidence of bearing dislocation was 4.1% (22/531). Patients with the symmetrical bearing displayed a relatively high dislocation rate of 9.6% (18/187), which significantly decreased to 1.1% (4/344) after changing to the anatomic bearing (P < .001). In the anatomic bearing group, the dislocation rate with the conventional phase III system was 1.4% (4/283). There were no bearing dislocations in the Microplasty system group (0%, 0/61) after at least 2 years of follow-up. Conclusion: Although mobile-bearing medial UKA was reported to have a high incidence of bearing dislocation in Asians, this frequency of dislocation is drastically decreased by bearing design and implantation system improvements. We consider mobile-bearing medial UKA appropriate for Asians. (C) 2019 Elsevier Inc. All rights reserved.
키워드
unicompartmental knee arthroplastymobile bearingOxford UKAcomplicationsbearing dislocationREPLACEMENT
식별자
- Scopus EID
- 2-s2.0-85077979641
- WoS UID
- 000528280800010



로그인
연구물 목록으로