Cerebral angiography using transauricular access in a rabbit model: a new technique
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- ACTA RADIOLOGICA62(1) · pp.113 · 2021
- 피인용
- Web of Science 0Scopus 1
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2020 1.99
- ISSN
- 0284-1851
저자
- 김학진제1저자Department of Radiology, Biomedical Research Institute, Pusan National University Hospital, Pusan National University College of Medicine, Busan, Republic of Korea
- 최선희Department of Radiology, Biomedical Research Institute, Pusan National University Hospital, Pusan National University College of Medicine, Busan, Republic of Korea
- 김소현Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, Republic of Korea
- 김용우교신저자Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Pusan National University College of Medicine, Yangsan, Republic of Korea
- 전병학Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, Republic of Korea
- 이득우Department of Nanomechatronics Engineering, Pusan National University, Busan, Republic of Korea
- 유진욱College of Pharmacy, Pusan National University, Busan, Republic of Korea
초록
Background Cerebral angiography in a rabbit model is widely used in the field of interventional radiology. Conventionally, the femoral artery is used for cerebral angiography in radiology departments. However, angiographic studies require surgical cutdown of the femoral artery, which is technically difficult. Purpose To evaluate a new cerebral angiography technique involving a transauricular approach in a rabbit model. Material and Methods In each of 10 rabbits, central auricular arteries were punctured in the right or left ear with a 20-gauge i.v. catheter. A microcatheter (2.0 F) with a 0.016-inch guide wire was introduced through the i.v. catheter and advanced to the aortic arch. The microcatheter and guide wire were advanced selectively into cerebral arteries and angiography was performed. Results Central auricular arteries were successfully punctured with 20-gauge i.v. catheters. After approaching the aortic arch, microcatheter tips and guide wires were advanced manually to cerebral arteries on both sides. Difficulties in selecting the carotid arteries were resolved by using a looping technique within the cardiac chamber. Microcatheter loops within the cardiac chamber disappeared or remained during artery superselection. Conclusion Transauricular cerebral angiography appears to be a feasible technique for brain or carotid intervention studies in rabbits. In addition, vertebral angiography using a transauricular approach is possible using the looping technique. Selection of carotid or vertebral arteries on each side was not difficult when the microcatheter and guide wire were looped within the cardiac chamber. The ear chosen for the initial puncture does not appear to be important.
키워드
Cerebral angiographytransauricular accesstechniquerabbitARTERIALEAR
식별자
- Scopus EID
- 2-s2.0-85083659497
- WoS UID
- 000527746300001



로그인
연구물 목록으로