Heat transfer enhancement and optimization of a tube fitted with twisted tape in a fin-and-tube heat exchanger
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY140(3) · pp.1015 · 2020
- 피인용
- Web of Science 20Scopus 20
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 2.731
- ISSN
- 1388-6150
저자
- 자라 하잡돌라히 우데제1저자School of Mechanical Engineering, Pusan National University, Busan, 609-735, Republic of Korea
- Hajabdollahi, HassanDepartment of Mechanical Engineering, Vali-e-Asr University of Rafsanjan, Rafsanjan, 7718897111, Iran
- 김경천교신저자School of Mechanical Engineering, Pusan National University, Busan, 609-735, Republic of Korea
초록
This research examines the effects of a tube fitted with twisted tape on the optimal design of a fin-and-tube heat exchanger (FTHE). The twisted tape on the tube side results in a trade-off between the heat transfer and pressure drop, so both the effectiveness (which is related to the rate of heat transfer) and the total annual cost (which is related to the heat transfer area and pressure drop) were optimized simultaneously. All the physical parameters of the FTHE were considered as design parameters, and the optimization was performed using a genetic algorithm for different mass flow rates of the tube side. All the optimum results in the case with the twisted tape tube (TTT) were compared with the case of a plain tube (PT). The optimum results show that the Pareto front for the case of the TTT was completely dominant over the PT for lower mass flow rate (0.25 kg s(-1)). Both the effectiveness and annual cost were enhanced in the TTT compared with the PT at the lower mass flow rate. On the other hand, for higher mass flow rates, there was a marginal point for effectiveness at which the Pareto front of TTT is dominant over that of the PT. For example, the TTT was optimal for effectiveness higher than 0.73, while the PT was optimal for effectiveness lower than 0.73 at a mass flow rate of 0.5 kg s(-1). For the low mass flow rate, the TTT is recommended for a wide range of effectiveness, while in the case of high mass flow rate, the TTT is recommended for just high effectiveness.
키워드
Fin-and-tube heat exchangerEffectivenessTotal annual costTwisted tape tubeMulti-objective optimizationTube-side mass flow ratePERFORMANCE EVALUATIONBIOLOGICAL NANOFLUIDENTROPY GENERATIONFLOWVISUALIZATIONLIQUIDSTEAM