굴삭기 냉각시스템 설계 평가를 위한 엔진룸 열유동 해석 검증

Verification of Engine Room Thermal Flow Analysis for Design Evaluation of Excavator Cooling System

문서 유형
연구출판물 · 학술지 논문
등재
KCI
저널
한국전산유체공학회지24(2) · pp.1 · 2019
피인용
KCI 1
ISSN
1598-6071

저자

  1. 이재석제1저자현대건설기계 선행기술부
  2. 서영민부산대학교
  3. 정찬혁현대건설기계 선행기술부
  4. 박용갑부산대학교
  5. 하만영교신저자부산대학교

초록

Basically, excavators perform high-load operation in a fixed place on the construction site and the cooling performance of an excavator is determined by a cooling system consisting of heat exchangers and a single fan which are located inside engine room. Therefore, during development of an excavator, it is really important to stably design the cooling system by estimating the heat sources of the excavator. In this study, CFD analysis of the engine room was carried out on four different types of excavators and the results of each CFD analysis were compared with those of the heat balance test. Based on the cooling performance index, which is defined by using the design reference temperature of each heat exchanger, the analysis error rate is up to approximately 10%. As these results, CFD analysis can be used to virtually evaluate excavator cooling performance and to perform design evaluation and verification of the cooling system.

키워드

굴삭기(Excavator)엔진룸(Engine Room)열평형시험(Heat Balance Test)전산유체역학(CFD)냉각성능지표(Cooling Performance Index)설계평가(Design Evaluation)