굴삭기 냉각시스템 설계 평가를 위한 엔진룸 열유동 해석 검증
Verification of Engine Room Thermal Flow Analysis for Design Evaluation of Excavator Cooling System
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널
- 한국전산유체공학회지24(2) · pp.1 · 2019
- 피인용
- KCI 1
- ISSN
- 1598-6071
저자
초록
Basically, excavators perform high-load operation in a fixed place on the construction site and the cooling performance of an excavator is determined by a cooling system consisting of heat exchangers and a single fan which are located inside engine room. Therefore, during development of an excavator, it is really important to stably design the cooling system by estimating the heat sources of the excavator. In this study, CFD analysis of the engine room was carried out on four different types of excavators and the results of each CFD analysis were compared with those of the heat balance test. Based on the cooling performance index, which is defined by using the design reference temperature of each heat exchanger, the analysis error rate is up to approximately 10%. As these results, CFD analysis can be used to virtually evaluate excavator cooling performance and to perform design evaluation and verification of the cooling system.
키워드
굴삭기(Excavator)엔진룸(Engine Room)열평형시험(Heat Balance Test)전산유체역학(CFD)냉각성능지표(Cooling Performance Index)설계평가(Design Evaluation)