본문 바로가기

Study on the Thermal Degradation Behavior of FKM O-rings

문서 유형
연구출판물 · 학술지 논문
등재
KCI
저널
엘라스토머 및 콤포지트53(4) · pp.213 · 2018
피인용
KCI 1
ISSN
2092-9676

저자

  1. 이진혁제1저자부산대학교
  2. 배종우한국신발피혁연구원
  3. 최명찬한국신발피혁연구원
  4. 윤유미한국신발피혁연구원
  5. 박성한국방과학연구소
  6. 조남주교신저자부산대학교

초록

The degradation mechanism and physical properties of an FKM O-ring were observed with thermal aging in this experiment. From X-ray photoelectron spectroscopy (XPS) analysis, we could observe carbon (285 eV), fluoro (688 eV), and oxygen (531 eV) peaks. Before thermal aging, the concentration of fluoro atoms was 51.23%, which decreased to 8.29% after thermal aging. The concentration of oxygen atoms increased from 3.16% to 20.39%. Under thermal aging, the FKM O-ring exhibited debonding of the fluoro-bond by oxidation. Analysis of the C1s, O1s, and F1s peaks revealed that the degradation reaction usually occurred at the C-F, C-F2, and C-F3 bonds, and generated a carboxyl group (-COOH) by oxidation. Due to the debonding reaction and decreasing mobility, the glass transition temperature of the FKM O-ring increased from −15.91°C to −13.79°C. From the intermittent CSR test, the initial sealing force was 2,149.6 N, which decreased to 1,156.2 N after thermal aging. Thus, under thermal aging, the sealing force decreased to 46.2%, compared with its initial state. This phenomenon was caused by the debonding reaction and decreasing mobility of the FKM O-ring. The S-S curve exhibited a 50% increase in modulus, with break at a low strain and stress state. This was also attributed to the decreasing mobility due to thermal aging degradation.

키워드

FKM O-ringX-ray photoelectron spectroscopyintermittent CSR methodsealing forceS-S curvedegradation

식별자

KCI
ART002425027