본문 바로가기

개방형 지열 시스템 설계법 개발을 위한 관정 주위 지중 온도 환경 검토

Study on the Underground Thermal Environment around Wells for a Design Method of Open-Loop Geothermal System

문서 유형
연구출판물 · 학술지 논문
등재
KCI
피인용
KCI 4
ISSN
2799-4783

저자

  1. 배상무제1저자부산대학교
  2. 남유진교신저자부산대학교
  3. 김홍교부산대학교
  4. 김현우부산대학교

초록

Groundwater heat pump (GWHP) system can achieve higher performance of the system by utilizing heat source of the annual constant groundwater temperature. The performance of GWHP system depends on the ground thermal environment such as groundwater temperature, groundwater flow rate and hydraulic conductivity. In this study, the geothermal environment was analyzed by using numerical simulation for develop the two-well geothermal system. As the result, this paper shows the change of the groundwater level and underground temperature around wells according to the conditions of flow rate and hydraulic conductivity.

키워드

Underground thermal environment(지중 열환경)Groundwater heat pump system (지하수이용 히트펌프 시스템)Numerical simulation(수치해석 시뮬레이션)

식별자

KCI
ART002203093