초록

This research analyzed the ventilation efect of the multi-span grenhouse based on the types of grenhouse structure, weather conditons, and locations inside the grenhouse. To compare and analyze the ventilation efects with diferent types of grenhouse, the uniform environmental conditons should be selected in advance. But these factors are not controled and require tense many precision facilties and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantiatively. In aditon, for the ventilation efect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the curent ventilation measurement method. The calculation eror of ventilation rate using TGD was low (10.5%). Thus, the TGD is very efective in calculating the ventilation eficiency. The wind direction of 90 degres showed the best ventilation efect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tol for simulating flow behavior in grenhouse.

키워드

Multi-span GrenhouseVentilation EfectsComputed Fluid Method