다연동 온실의 자연환기효율성 비교 분석
Comparative Study on Eficiencies of Naturaly-Ventilated Multi-Span Grenhouses in Korea
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널
- 한국산업융합학회논문집20(1) · pp.8 · 2017
- 피인용
- KCI 0
- ISSN
- 1226-833X
저자
초록
This research analyzed the ventilation efect of the multi-span grenhouse based on the types of grenhouse structure, weather conditons, and locations inside the grenhouse. To compare and analyze the ventilation efects with diferent types of grenhouse, the uniform environmental conditons should be selected in advance. But these factors are not controled and require tense many precision facilties and labor forces. Thus, the CFD simulation was used for the air stream to be analyzed qualitatively and quantiatively. In aditon, for the ventilation efect analysis, the TGD (Tracer Gas Decay) was used to overcome the shortcomings of the curent ventilation measurement method. The calculation eror of ventilation rate using TGD was low (10.5%). Thus, the TGD is very efective in calculating the ventilation eficiency. The wind direction of 90 degres showed the best ventilation efect. The ventilation rate also decreased along the air circulation path, and the rate was the lowest around the outlet. The computed fluid method (CFD) turned out to be a power tol for simulating flow behavior in grenhouse.
키워드
식별자
- KCI
- ART002213637