본문 바로가기

Numerical study of the pulsatile flow depending on non-Newtonian viscosity in a stenosed microchannel

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
JOURNAL OF VISUALIZATION23(1) · pp.61 · 2020
피인용
Web of Science 18Scopus 17
FWCI (Scopus)
0
JCR IF
JCR 2019 0.926
ISSN
1343-8875

저자

  1. 하이경제1저자College of Nursing, Pusan National University, Yangsan, South Korea
  2. 홍현지College of Nursing, Pusan National University, Yangsan, South Korea
  3. 염은섭교신저자College of Nursing, Pusan National University, Yangsan, South Korea
  4. 송재민Department of Oral and Maxillofacial Surgery, School of Dentistry, Pusan National University, Yangsan, South Korea

초록

Considering the shear-thinning feature of blood viscosity, the characteristics of non-Newtonian fluids are important in pulsatile blood flows. Stenosis, with an abnormal narrowing of the vessel, blocks blood flow to downstream tissues and leads to plaque rupture. In smaller arteries of diameters up to a few hundred micrometers, such stenosis can result in severe consequences. Therefore, a systematic analysis of the blood flow around the stenosed microchannel is important. In this study, non-Newtonian behaviors of the blood flow around a microchannel of diameter 500 mu m, with 60% severe stenosis, were examined using CFX under pulsatile flow condition, with a period of 1 s and Reynolds number of 14.025 at the systolic phase. The viscosity information of the two non-Newtonian samples and the used pulsatile profile were based on our previous study. For comparison, water at room temperature was used as the Newtonian fluid. During the pulsatile phase, wall shear stress (WSS) is highly oscillated. In the case of the water flow, the recirculation occurred downstream the stenosis. This recirculation made the vortex structures travel the longest and induced a low WSS distribution and rapid normalized pressure drop at downstream of the stenosis. Conversely, the non-Newtonian feature of viscosity made flow structures almost symmetric, with respect to the stenosis. However, the highly oscillating WSS enhances the tendency of plaque instability and damage to the endothelium. Our findings on the influence of blood viscosity on stenotic lesions may help clinicians understand relevant mechanisms. Graphic abstract

키워드

Non-Newtonian fluidsStenosisWall shear stressPulsatile flowWALL SHEAR-STRESSBLOOD-FLOWERYTHROCYTE AGGREGATIONARTERYMODELFLUIDPATHOPHYSIOLOGYENLARGEMENTRHEOLOGYINDEX

식별자

Scopus EID
2-s2.0-85072049642
WoS UID
000513298100006