Corrugated cooling unit for accelerated cooling of rebar subjected to Tempcore process
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- APPLIED THERMAL ENGINEERING167 · 2020
- 피인용
- Web of Science 3Scopus 4
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 4.725
- ISSN
- 1359-4311
저자
- Park, Chun Su제1저자R&D Center, Dongkuk Steel, 70 Geonposaneop-ro, 3214beon-gil, Nam-gu, Pohang, Gyeongsangbuk-do, Republic of Korea
- Bae, Seh WookR&D Center, Dongkuk Steel, 70 Geonposaneop-ro, 3214beon-gil, Nam-gu, Pohang, Gyeongsangbuk-do, Republic of Korea
- Cho, Jin RaeDepartment of Naval Architecture & Ocean Engineering, Hongik University, 2639 Sejongro, Jochiwon 30016, Republic of Korea
- 이하범School of Mechanical Engineering, Pusan National University, 30 Jangjeon-dong, Geumjeong-gu, Busan 46241, Republic of Korea
- 김양진School of Mechanical Engineering, Pusan National University, 30 Jangjeon-dong, Geumjeong-gu, Busan 46241, Republic of Korea
- 문영훈교신저자School of Mechanical Engineering, Pusan National University, 30 Jangjeon-dong, Geumjeong-gu, Busan 46241, Republic of Korea
초록
An advanced cooling unit was developed and characterized to accelerate the cooling of steel rebars during the Tempcore process. Compared to conventional flat-surfaced coolers, the newly developed cooling unit uses a corrugated surface to generate turbulence. To estimate the cooling performance of the corrugated cooler, the heat transfer coefficient during the Tempcore process was obtained using a finite-volume method. The turbulence induced by the corrugated cooler reduces the vapor volume fractions and increases the heat transfer coefficient by up to 10%. The obtained heat transfer coefficient for convective and nucleate boiling was then applied in the model to predict the volume of martensite formed in the outer layer of the bar after the Tempcore process. The corrugated cooling unit was assembled and incorporated into an experimental simulator to evaluate its ability to accelerate cooling of rebars. For rebars treated in the corrugated cooler, a 6.54% increase in the martensite volume fraction with a 13 degrees C decrease in the self-tempering temperature was achieved. This result confirms that the developed corrugated cooler can be a reasonable alternative to increase cooling efficiency of Tempcore facility without upgrading the capacity of the water supplying system.
키워드
TempcoreRebarCorrugated coolerHeat transfer coefficientThermal modelTemperingDUCTILE R.C. STRUCTURESHEAT-TRANSFERMECHANICAL-BEHAVIORTENSILE PROPERTIESPREDICTIONMODELFLOWSIMULATIONDEPARTUREMETAL
식별자
- Scopus EID
- 2-s2.0-85075918621
- WoS UID
- 000513289700059



로그인
연구물 목록으로