본문 바로가기

A study on the optimal arrangement of tube bundle for the performance enhancement of a steam turbine surface condenser

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 16Scopus 19
FWCI (Scopus)
0
JCR IF
JCR 2019 4.725
ISSN
1359-4311

저자

  1. 박용갑제1저자Rolls-Royce and Pusan National University Technology Centre in Thermal Management, Pusan National University, Busan 46241, Republic of Korea
  2. 윤상열Rolls-Royce and Pusan National University Technology Centre in Thermal Management, Pusan National University, Busan 46241, Republic of Korea
  3. 서영민교신저자Rolls-Royce and Pusan National University Technology Centre in Thermal Management, Pusan National University, Busan 46241, Republic of Korea
  4. 하만영School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
  5. Park, Young MinTechnology Development Part II R&D Center, Donghwa Entec, Busan 46753, Republic of Korea
  6. Koo, Byoung SooTechnology Development Part II R&D Center, Donghwa Entec, Busan 46753, Republic of Korea

초록

A porous medium model was used for numerical and experimental investigations of a system that includes a tube bundle inside a steam turbine surface condenser. A condensation model was developed to predict the condenser performance using user-defined functions (UDFs) in the commercial computational fluid dynamics software FLUENT. The shell-side pressure drop around the tube bundle is an important indicator for the condenser performance and can be used to compare different condenser-tube arrangements. The condenser performance was analyzed using various numerical results, such as the absolute pressure, condensation mass flow rate, velocity magnitude, and air mass fraction. Detailed effects of the various parameters of tube bundle are discussed. These parameters had a great influence on the condenser performance. The numerical data were generally in good agreement with those obtained by experiments. An important practical finding from this study is that changing tube bundle can significantly improve the condenser performance by reducing the shell-side pressure drop. Consequently, the optimized model has approximately 40% better pressure drop performance than the base model, and the numerical results were verified with the experiments established by Donghwa Entec.

키워드

Steam surface condenserTube arrangementPorous mediaThermal resistance networkCondensationHEAT-TRANSFER2-PHASE FLOWNUMERICAL-MODELSYSTEMSIMULATIONPREDICTIONEJECTORPUMPAIR

식별자

Scopus EID
2-s2.0-85075853841
WoS UID
000512220900070