Design of a Lumbar Interspinous Fixation Device for Minimally Invasive Surgery and Spine Motion Stabilization
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q4Scopus Q3
- 저널
- JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING40(1) · pp.1 · 2020
- 피인용
- Web of Science 2Scopus 2
- FWCI (Scopus)
- 0
- JCR IF
- JCR 2019 1.173
- ISSN
- 1609-0985
저자
- 허민혁제1저자School of Mechanical Engineering, Pusan National University, Busan, South Korea
- 윤지환School of Mechanical Engineering, Pusan National University, Busan, South Korea
- 박상후School of Mechanical Engineering, Pusan National University, Busan, South Korea
- 최윤석Department of Materials Science & Engineering, Pusan National University, Busan, South Korea
- Lee, Sang-SooHallym University-Chuncheon Sacred Heart Hospital, Institute for Skeletal Aging & Orthopedic Surgery, Chuncheon, South Korea
- 박성훈교신저자School of Mechanical Engineering, Pusan National University, Busan, South Korea
초록
Background Intervertebral fusion removes a considerable region of lumbar ligaments and muscles and increases degenerative diseases in adjacent segments. Therefore, an interspinous fixation device must be developed to overcome these drawbacks. The purpose of the present study is to design a lumbar spine interspinous fixation device that minimizes both tissue removal during interspinous fixation surgery and degenerative changes of adjacent lumbar segments after the surgery. Methods The lumbar interspinous fixation device was designed by employing spike and ratchet structures in the device fixation part to minimize the removal of soft tissue during interspinous fixation surgery and to reduce the stress concentration after the surgery. The part connecting two spinous processes was designed as spring element to allowing normal lumbar behavior after the surgery. Finite element analysis was performed to design spring elements, confirm the structural stability of the fixation device, and compute the intervertebral disc pressure and flexion-extension motions of intact and defect lumbar vertebrae models that were validated in this study. Results The structural stability of the currently designed interspinous fixation device was confirmed. Under physiological loading conditions, the maximum displacement is 0.4 mm and the maximum stress is 173.5 MPa under the maximum load of 250 N, which accounts for 18.3% of the yield strength of the LIFD material (950 MPa). When the interspinous fixation device was inserted, the intervertebral disc pressure was reduced by 80-92% compared with the defect model that mimics intervertebral fusion. Both a significant reduction in the flexion motion (from 10.7 degrees to 6.0 degrees) up to the normal behavior and a minimal reduction in the extension motion (from - 4.6 degrees to - 3.1 degrees) were achieved, which is consistent with the main role of the LIFD reported in the literature. Conclusions The interspinous fixation device designed in this work, which is structurally stable and can minimize the tissue removal during interspinous fixation surgery, can reduce the intervertebral disc pressure and maintain the normal lumbar behavior. Therefore, the device can minimize degenerative diseases in adjacent lumbar segments of lumbar vertebrae after the surgery.
키워드
Lumbar interspinous fixation deviceLumbar spineMinimally invasive surgerySpine stabilizationSpine implantFINITE-ELEMENTDYNAMIC STABILIZATIONMECHANICAL-PROPERTIESINTERVERTEBRAL DISCGRAF LIGAMENTOPLASTYSCREW FIXATIONFOLLOW-UPPRESSUREBIOMECHANICSCOMPRESSION