본문 바로가기

Comparison of glaucoma diagnostic ability of ganglion cell-inner plexiform layer according to the range around the fovea

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
BMC OPHTHALMOLOGY19(1) · 2019
피인용
Web of Science 3Scopus 3
FWCI (Scopus)
0.28
JCR IF
JCR 2018 1.431
ISSN
1471-2415

저자

  1. 정재호제1저자Department of Ophthalmology, College of Medicine, Seoul National University Hospital Seoul South Korea
  2. Seo, Je HyunDepartment of Ophthalmology, Veterans Medical Research Institute, Veterans Health Service Medical Center Seoul South Korea
  3. 강민승(안과)Department of Ophthalmology, College of Medicine, Pusan National University Yangsan Hospital Yangsan South Korea
  4. 신종훈교신저자Department of Ophthalmology, College of Medicine, Pusan National University Yangsan Hospital Yangsan South Korea

초록

Background: To compare the glaucoma diagnostic ability of the ganglion cell-inner plexiform layer (GCIPL) thickness depending on the range around the fovea using wide-angle, swept-source optical coherence tomography (SS-OCT). Methods: We compared the glaucoma diagnostic utility of GCIPL parameters across multiple regions while centered on the fovea. In a wide-angle scan, the GCIPL for each 1-mm(2) grid square of a 12 x 9 mm(2) scan resulted in 108 data points. With respect to the range of the GCIPL measurements around the macula, the wide-angle scan images were classified into three zones. Zone 1 was defined as a narrow area; zone 2 was defined as a mid-sized area; and zone 3 was defined as a wide area. We recorded the quadrant GCIPL thickness, average, and minimum quadrant GCIPL within each zone. The areas under the receiver operating characteristic (AUROCs) curves were calculated to evaluate the glaucoma diagnostic utility. Results: Sixty-one eyes with glaucoma and 59 normal eyes were assessed. The minimum and average GCIPL measurements in zones 1-3 in eyes with glaucoma were significantly lower than those in normal eyes (P < 0.001). The AUROCs for the minimum and inferotemporal GCIPL in zone 1 and the inferotemporal GCIPL thickness in zone 2 were greater than 0.9 (0.945, 0.931, and 0.918, respectively). Conclusions: Wide-angle scanning using SS-OCT will contribute to improvements in the detection of glaucomatous damage. The minimum and inferotemporal GCIPL in zone 1 may be more useful for detecting glaucoma than those in the conventional area.

키워드

GlaucomaGanglion cell-inner plexiform layerWide-angle swept-source OCTNERVE-FIBER LAYEROPTICAL COHERENCE TOMOGRAPHYTHICKNESSACCURACYDAMAGEDEFECTSWIDE

식별자

Scopus EID
2-s2.0-85077337842
WoS UID
000510605500004