FeSe quantum dots for in vivo multiphoton biomedical imaging
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- Nature IndexSCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- SCIENCE ADVANCES5(12) · 2019
- 피인용
- Web of Science 62Scopus 65
- FWCI (Scopus)
- 1.32
- JCR IF
- JCR 2018 12.804
- ISSN
- 2375-2548
저자
- 권준영제1저자Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, 46240, Republic of Korea
- 전승원Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, 46240, Republic of Korea
- Choi, S. I.Division of Convergence Technology, National Cancer Center, Goyang, 10408, Republic of Korea
- Mao, X.College of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China
- Kim, J.Department of Chemistry, Chungnam National University, Daejeon, 34134, Republic of Korea
- 고은경Department of Biomaterial Science, Pusan National University, Miryang, 50463, Republic of Korea
- Kim, Y. H.Division of Convergence Technology, National Cancer Center, Goyang, 10408, Republic of Korea
- Kim, S. K.Division of Convergence Technology, National Cancer Center, Goyang, 10408, Republic of Korea
- 황대연Department of Biomaterial Science, Pusan National University, Miryang, 50463, Republic of Korea
- 김창석Department of Cogno-Mechatronics Engineering, Pusan National University, Busan, 46240, Republic of Korea
- 이재범교신저자Department of Chemistry, Chungnam National University, Daejeon, 34134, Republic of Korea
초록
An immense demand in biomedical imaging is to develop efficient photoluminescent probes with high biocompatibility and quantum yield, as well as multiphoton absorption performance to improve penetration depth and spatial resolution. Here, iron selenide (FeSe) quantum dots (QDs) are reported to meet these criteria. The synthesized QDs exhibit two- and three-photon excitation property at 800- and 1080-nm wavelengths and high quantum yield (ca. 40%), which are suitable for second-window imaging. To verify their biosuitability, poly(ethylene glycol)-conjugated QDs were linked with human epidermal growth factor receptor 2 (HER2) antibodies for in vitro/in vivo two-photon imaging in HER2-overexpressed MCF7 cells and a xenograft breast tumor model in mice. Imaging was successfully carried out at a depth of up to 500 mu m from the skin using a nonlinear femtosecond laser at an excitation wavelength of 800 nm. These findings may open up a way to apply biocompatible FeSe QDs to multiphoton cancer imaging.