본문 바로가기

Effect of spray nozzle position on pad temperature distribution and wafer non-uniformity

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY33(12) · pp.5677 · 2019
피인용
Web of Science 1Scopus 1KCI 0
FWCI (Scopus)
0
JCR IF
JCR 2018 1.221
ISSN
1738-494X

저자

  1. 이기훈제1저자School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  2. 이다솔School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  3. 정선호School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  4. 이동환School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea
  5. 정해도교신저자School of Mechanical Engineering, Pusan National University, Busan, 46241, Korea

초록

During chemical mechanical planarization (CMP), the pad surface temperature generally increases due to the friction between the wafer and the pad. A pad with a large sliding distance generates more heat compared to pad with small sliding distance. A nonuniform temperature distribution on the pad causes its mechanical properties to become uneven, which are affected by within-wafer non-uniformity (WIWNU). This study aims to improve the polishing uniformity by controlling the temperature profile of the pad surface for each spray nozzle position. When the slurry was sprayed on an area for which a large slide distance was measured, a uniform temperature distribution and improved WIWNU were obtained.

키워드

CMPSpray nozzleCooling effectTemperature profileWIWNUSLURRY NOZZLEHEAT

식별자

Scopus EID
2-s2.0-85077205579
WoS UID
000504965100010
KCI